[66]Ambush Report Code
Program a
Enhanced Communicator Features
[67]Telephone Number 1
(1) Opening After Alarm (Cancel Code) - When enabled, all users that are not selected to report on Opening/Closing [39] will report an Opening only when opening after an alarm has occurred.
(2)Conditional Closing Telephone 1 - When enabled, all users that are not selected to report an Opening/Closing ([39], [59]) will report a Closing only when zones have been bypassed. The Zone Trouble Code
(3)Reserved
(4)Reserved
[68]Telephone Number 3
(1)Opening after Alarm (Cancel Code) - see
(2)Conditional Closing Telco 3 - see [67-
1].
(3)Reserved
(4)Reserved
Wireless
Up to two receivers can be wired to the XP-
400.Each wireless transmitter can be mapped to a zone. Only 1 wireless device is permitted per zone, however, the use of both hardwired and wireless on a zone is permitted.
To Map a transmitter to a zone:
1.Enter the Programming Block Number that the transmitter is to be mapped to.
2.Enter the
A transmitter will send a transmission every time it is tripped. The transmitter also sends a supervisory transmission about once every hour. If the receiver does not receive a signal from a transmitter in the time programmed in Wireless Supervisory Timer, a system trouble ’RF Supervisory Failure' will be indicated at the keypad.
Program Wireless Supervisory Timer [16] to change the supervisory time from the default of 12 hours.
The Signal strength of a transmitter can be checked at the keypad (see A7 Fault
Find Mode).
19