Napco Security Technologies XP-400 Enhanced Communicator Features, Wireless, 66Ambush Report Code

Models: XP-400

1 28
Download 28 pages 54.33 Kb
Page 19
Image 19
[66]Ambush Report Code

[66]Ambush Report Code

Program a 2-digit report code for Ambush. To send an ambush report, program a User Code for User 4, Program report User 4 as Ambush [20-4] and Select reporting for Telco 1 [36-2] and/or Telco 3 [56-2].

Enhanced Communicator Features

[67]Telephone Number 1

(1) Opening After Alarm (Cancel Code) - When enabled, all users that are not selected to report on Opening/Closing [39] will report an Opening only when opening after an alarm has occurred.

(2)Conditional Closing Telephone 1 - When enabled, all users that are not selected to report an Opening/Closing ([39], [59]) will report a Closing only when zones have been bypassed. The Zone Trouble Code [62-2] is used to report zones that have been bypassed at the time of the closing report.

(3)Reserved

(4)Reserved

[68]Telephone Number 3

(1)Opening after Alarm (Cancel Code) - see [67-1].

(2)Conditional Closing Telco 3 - see [67-

1].

(3)Reserved

(4)Reserved

Wireless

Up to two receivers can be wired to the XP-

400.Each wireless transmitter can be mapped to a zone. Only 1 wireless device is permitted per zone, however, the use of both hardwired and wireless on a zone is permitted.

To Map a transmitter to a zone:

1.Enter the Programming Block Number that the transmitter is to be mapped to.

2.Enter the 7-digit RF ID number directly, just as it is shown on the device label. After the 7th digit is entered the keypad will beep.

A transmitter will send a transmission every time it is tripped. The transmitter also sends a supervisory transmission about once every hour. If the receiver does not receive a signal from a transmitter in the time programmed in Wireless Supervisory Timer, a system trouble ’RF Supervisory Failure' will be indicated at the keypad.

Program Wireless Supervisory Timer [16] to change the supervisory time from the default of 12 hours.

The Signal strength of a transmitter can be checked at the keypad (see A7 Fault

Find Mode).