System Troubles

 

Keypad Beeps or

Zone LED

System Trouble

Cause/Action

 

 

H SYSTEM

ON

Condition

 

 

 

 

 

 

 

 

Flashes

 

 

 

 

 

 

 

 

 

 

 

1 Beep

1

Y AC Power Failure

This trouble will occur if AC power is not present. Ensure that the transformer is connected to an unswitched power source.

 

 

Y LED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Low Battery

If there has been a recent power failure, the battery may be partially depleted and must be recharged by the control panel. If

 

 

 

 

 

the trouble does not go away in 24 hours, replace the battery.

 

 

 

 

 

 

 

 

 

3

Communication

The system was not able to report to central station. Check panel programming and telephone line wiring. The trouble will

 

 

 

 

Failure/PCPreset Fail

clear after it has been acknowledged by viewing the system trouble as long as the telephone line has passed a line cut test

 

 

 

 

(tested automatically by the panel). The Panel did not sucsessfully connect and download/upload with the commputer

 

 

 

 

 

running PCPreset - check Auto Download ID number, Callback Number or PCPreset Setup.

 

 

 

4

Telephone Line Cut

The telephone line has failed. If telephone service has been temporarily interrupted, the trouble will clear when restored and

 

 

 

 

 

acknowledged by viewing the system trouble.

 

 

 

 

 

 

 

 

2 Beeps

1

Bell/Siren line Cut

There is a problem with the Bell or Siren wiring. EOL2.2K resistor must be installed.

 

 

 

 

 

 

 

 

 

3

Rcvr Fail-to-Respond/Rcvr

The receiver is not responding to the panel. The red LED on the receiver should be flashing, refer to WI848. The cover is off

 

 

 

 

Tamper

the receiver causing a tamper signal to be transmitted.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Receiver Jam

A signal is blocking the normal reception of transmissions from the wireless devices. Ensure that the green LED on the

 

 

 

 

 

receiver is not on continuously, refer to receiver manual WI848.

 

 

 

 

 

 

 

 

3 Beeps

1-4

Wireless

The battery in the wireless transmitter is low and should be replaced. This transmitter is on the zone corresponding to the

 

 

 

 

Transmitter Low Battery

number of the zone light flashing. The replacement battery for the GEM Trans2 door/window transmitter and the GEM PIR

 

 

 

 

wireless motion detector is the Duracell DL123A. (2 required for the GEM-PIR) WARNING: Replace batteries only with the

 

 

 

 

 

same type as specified above. Use of another battery may present a risk of fire or explosion. Do not recharge or disassemble

 

 

 

 

 

battery or dispose of in fire.

 

 

4 Beeps

1-4

Wireless

The panel has not received a supervisory signal from the transmitter within the time programmed. Check Wireless

 

 

 

 

Transmitter

Supervisory Timer [16] Programming. Check the placement of the transmitter and receiver, refer to WI848.

 

 

 

 

 

 

 

 

 

Supervisory Failure

 

 

 

 

 

 

 

 

 

7 Beeps

1-4

Zone Trouble

The panel has one or more of the following 3 possible troubles: Zone Short, Transmitter Tamper or Dual Tech Self Test Fail.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 