Napco Security Technologies XP-400 System Times, System Features, 08PGM Output, 10Exit Delay

Models: XP-400

1 28
Download 28 pages 54.33 Kb
Page 13
Image 13
[08]PGM Output

[08]PGM Output

Enables the PGM Output on a zone trip for each zone selected. The PGM Output will remain ON until reset.

System Times

[10]Exit Delay

The delay time which permits exit through an Exit/Entry Zone [00] after the system is armed, allows a user to leave the premises without setting off an immediate alarm. Exit Delay may be programmed for up to 255 seconds (4¼ minutes); a value of 0 defaults to 60 seconds.

[11]Entry Delay

Delay time permits entry through Exit/Entry Zone(s) after the system is armed without setting off an immediate alarm. Entry Delay allows the user time to enter and disarm the system. Upon entering, the keypad sounder will sound a steady tone (Entry Sound) to remind the user to disarm the system. Entry Delay Time [11] may be programmed for up to 255 seconds (4¼ minutes); a value of 0 defaults to 30 seconds. Entry Delay

may be canceled by pressing a4before or after arming.

[12]Burg (Steady) Output Time-out

Can be programmed from 1 to 255 min (4¼ hours); 0 means output will stay ON until turned off by entering an Arm/Disarm Code.

[13]Reserved

[14]Test Timer Interval

Program the interval, in days, between Test Timer reports. Test Timer Interval may be programmed from 1 to 255 days.

[15]Line Cut Time-to-Fail

Enable this feature by programming the delay time required to declare a line cut failure. Programming 000 will disable line cut detection.

[16]Wireless Supervisory Timer

A transmitter will send a transmission every time it is tripped; when there is no activity, the transmitter sends a supervisory transmission about once an hour. If the receiver does not receive any signal (either

a trip or a status) from a transmitter in the time specified, a system trouble ‘RF Supervisory Failure' will be indicated at the keypad. Timer is programmable from 1-26 hours; 0 means NO supervision.

System Features

[20]Keypad Features 1

(1)Enable Keypad Panic 2 (KK) Additional Programming required:

Select reporting to Telco 1 [36-1] or Telco 3 [56-1].

(2)Enable Keypad AUX (ff)

Additional Programming required:

Select reporting to Telco 1 [36-2] or Telco 3 [56-2].

(3)Enable Keypad Panic (gG) Additional Programming required:

Select reporting to Telco 1 [36-3] or Telco 3 [56-3].

(4)Enable Ambush - If enabled, the 4th User Code will send an Ambush report when entered to disarm the system. Additional Programming required: Program User 4 Arm/ Disarm Code. Select reporting to Telco 1 [36- 2] or Telco 3 [56-2].

13