Napco Security Technologies Dealer Programming, WI1370 XP-400Installation Instructions

Models: XP-400

1 28
Download 28 pages 54.33 Kb
Page 22
Image 22
Dealer Programming

WI1370 XP-400 Installation Instructions

Site

At the site perform the following three steps:

1.Arm the panel.

2.Disarm the panel.

3.Enter A6. The panel will now call

the download computer running PCPreset. PCPreset will answer the call, establish a connection, and then download the account that matches the Auto Download ID Number [93] with the account of the same number in the list that PCPreset is currently running.

Dealer Programming

[94]Dealer Code

The default Dealer Code is 4567. Program a new 4-digit Dealer Code. When the panel is defaulted the Dealer Code will be changed back to the default Dealer Code of 4567 only if Dealer Code Lockout [96-1] has not been programmed.

[95]User 1 Code

The 1st User code is a program code as well as an Arm/Disarm code. The default User Code is 1234. If User 1 Code Lockout is programmed the User 1 Code cannot be programmed from User Program Mode.

[96]Dealer Options 1

(1)Dealer Code Lockout - Program to prevent the Dealer Code from changing with a panel default.

(2)User 1 Code Lockout - If programmed the User 1 Code cannot be programmed from User Program Mode.

(3)Reserved

(4)Reserved

[97]Dealer Options 2

(1)International Dialing Protocol - No dialing if no dial tone, 60 seconds between attempts and 4 s wait for dial tone.

(2)Invert Bell Output - Inverts the Bell polarity and removes supervision from the bell circuit.

(3)System Trouble Auto Restore - Normally, System troubles require acknowledgment (View System Trouble) in order to restore. If this option is selected troubles will restore without requiring acknowledgment.

(4)User 1 Code-Program only - If enabled User 1 Code will function only as the User Program Code and will not Arm/Disarm the panel.

Note: All programming within Programming Blocks [96] & [97] will not change if the panel is defaulted.

[98] Number of Re-Dials

The Number of re-dial attempts made by the panel before indicating a Fail-to- Communicate.

22

Page 22
Image 22
Napco Security Technologies Dealer Programming, WI1370 XP-400Installation Instructions, 94Dealer Code, 95User 1 Code