Napco Security Technologies XP-400 Keypad Operation, Panel Operation, PGM Wiring, Keypad Sounder

Models: XP-400

1 28
Download 28 pages 54.33 Kb
Page 7
Image 7
PGM Wiring

PGM Wiring

The PGM is a switched negative output that is activated depending on the programming option

(s)that have been selected [08], [23] - [25]. Connect the device controlled by the PGM between +PWR and the PGM terminal (maximum load of 50 mA).

Keypad Operation

Keypad zone LEDs indicate zone status. W ARMED, X READY and HSYSTEM LEDs

provide system status. The keypad sounder provides feedback beeps for correct and incorrect entries.

Keypad Sounder

3 QUICK BEEPS

Panel Armed (System ON)

Chime ON

Fault Find Mode ON

Keypad Sounder ON

Zone Bypassed

6 QUICK BEEPS

Panel Disarmed (System OFF)

Chime OFF

Fault Find Mode OFF

Keypad Sounder OFF

Zone Un-Bypassed

1 SECOND - STEADY TONE

Incorrect Code Entered

Invalid key entry

4LONG BEEPS (PRIORITY CONDITION)

1.Entering an Arm Code with a faulted zone (Not an Auto-Bypass Reentry Zone).

2.Entering an Arm Code when the Bell or PGM is ON (Bell and PGM will turn OFF).

Keypad LEDs

W ARMED LED DEFINITION

 

Armed

ON

Instant Mode

Rapid Flash

Zone in Alarm

Flashing

X READY LED DEFINITION

 

Ready to be Armed

ON

Zone faulted

OFF

H SYSTEM LED DEFINITION

AC Failure

Flashing

System Trouble(s)

ON

ZONE LED DEFINITION

 

Faulted Zone

ON

Bypassed Zone

Slow Flash

Zone in Alarm

Flashing

Panel Operation

Arming (System ON)

Before arming the system, close all protected zones (unless programmed as Auto-Bypass Reentry Zones). Enter a 4-digit Arm/Disarm code (the keypad will provide a feedback beep for each key pressed). If a valid Arm/Disarm code is entered, the keypad will beep 3 times. If an incorrect Arm/Disarm code is entered, the keypad will sound a 1-second tone indicating an incorrect entry.

Arming without Entry Delay (Instant Mode)

Enter the A1 to eliminate the entry delay. The ARMED LED will flash rapidly to indicate the panel is in Instant Mode. If an Exit/Entry Zone is tripped while the panel is in Instant Mode the panel will go into alarm immediately.

7

Page 7
Image 7
Napco Security Technologies XP-400 Keypad Operation, Panel Operation, PGM Wiring, Keypad Sounder, Keypad LEDs