PGM Wiring
The PGM is a switched negative output that is activated depending on the programming option
(s)that have been selected [08], [23] - [25]. Connect the device controlled by the PGM between +PWR and the PGM terminal (maximum load of 50 mA).
Keypad Operation
Keypad zone LEDs indicate zone status. W ARMED, X READY and HSYSTEM LEDs
provide system status. The keypad sounder provides feedback beeps for correct and incorrect entries.
Keypad Sounder
3 QUICK BEEPS
Panel Armed (System ON)
Chime ON
Fault Find Mode ON
Keypad Sounder ON
Zone Bypassed
6 QUICK BEEPS
Panel Disarmed (System OFF)
Chime OFF
Fault Find Mode OFF
Keypad Sounder OFF
Zone
1 SECOND - STEADY TONE
Incorrect Code Entered
Invalid key entry
4LONG BEEPS (PRIORITY CONDITION)
1.Entering an Arm Code with a faulted zone (Not an
2.Entering an Arm Code when the Bell or PGM is ON (Bell and PGM will turn OFF).
Keypad LEDs
W ARMED LED DEFINITION |
|
Armed | ON |
Instant Mode | Rapid Flash |
Zone in Alarm | Flashing |
X READY LED DEFINITION |
|
Ready to be Armed | ON |
Zone faulted | OFF |
H SYSTEM LED DEFINITION | |
AC Failure | Flashing |
System Trouble(s) | ON |
ZONE LED DEFINITION |
|
Faulted Zone | ON |
Bypassed Zone | Slow Flash |
Zone in Alarm | Flashing |
Panel Operation
Arming (System ON)
Before arming the system, close all protected zones (unless programmed as
Arming without Entry Delay (Instant Mode)
Enter the A1 to eliminate the entry delay. The ARMED LED will flash rapidly to indicate the panel is in Instant Mode. If an Exit/Entry Zone is tripped while the panel is in Instant Mode the panel will go into alarm immediately.
7