Dealer Commands

A6 Download (Programming Required)

Establish a connection between the PCD phone line and the Control Panel phone line. When ready, tell the installer to arm, then disarm. Then enter A6 in order to establish a connection. Phone connection to installer will go "dead" as downloader and panel connect.

A7Fault Find ON/OFF

Hardwired Zone Operation

Enter this command to turn Fault Find ON/OFF. While in Fault Find mode, the loop response for all zones will be set to the faster response of 40 ms. The keypad will beep for .25-seconds when hardwired zones are faulted and for 1-second when zones are restored.

of 4 to 10, with 4 being marginal and 10 being excellent.

The keypad will beep out a number, from 1-4, corresponding to the signal strength of the transmitter. See Table 5 below. Each beep is 1- second long. The keypad will sound a short beep for transmitters with signal strengths of 3 or less.

SIGNAL STRENGTH

KEYPAD SOUNDER

3 or less

.25S BEEP

 

 

4

BEEP

5

BEEP BEEP

6-7

BEEP BEEP BEEP

 

 

8-10

BEEP BEEP BEEP BEEP

TABLE 5 AUDIBLE SIGNAL STRENGTH INDICATION

Zone Features

[00]Exit/Entry Zones

Delay allows exit and entry through an Exit/ Entry Zone after the system is armed without setting off an immediate alarm. Exit Delay allows the user to leave the premises after arming. Entry Delay allows the user time to enter and disarm. The entry delay may be canceled by pressing a4.

[01]Home/Away with Delay Zones

Zones that automatically bypass at the expiration of the exit delay if the EXIT/ ENTRY zone(s) are not violated. Zones of this type have a three (3) minute power-up delay, and do not display or cause an alarm if faulted when the system powers up. Pressing the bkey cancels the 3 minute

Wireless Operation (Signal Strength)

ZONE 1

ZONE 2

ZONE 3

ZONE 4

ZONE 1

ZONE 2

ZONE 3

ZONE 4

ZONE 1

ZONE 2

ZONE 3

ZONE 4

ZONE 1

ZONE 2

ZONE 3

ZONE 4

timer.

If Exit/Entry zone(s) are violated during the exit delay, zones programmed as Home/ Away with Delay Zone(s) will have a fixed

While in Fault Find mode the keypad will provide an audible (Table 5) and visual (Figure 4) indication of each transmitter’s signal strength. The signal strength metering is based on a scale

4

5

6-7

8-10

FIGURE 4 VISUAL SIGNAL STRENGTH INDICATION ( = LED on; = LED off).

20-second entry delay, if violated before the Exit/Entry zone.

11

Page 11
Image 11
Napco Security Technologies XP-400 Dealer Commands, Zone Features, Wireless Operation Signal Strength

XP-400 specifications

Napco Security Technologies has established itself as a leading name in the field of security solutions, and one of its standout products is the XP-400, a cutting-edge alarm panel designed for modern security applications.

The Napco XP-400 is recognized for its robust performance and versatility, making it suitable for both residential and commercial security systems. At the heart of its design is an advanced microprocessor that ensures seamless operation and efficient processing of security signals. This intelligent technology allows for faster response times and greater reliability compared to traditional panels.

One of the main features of the XP-400 is its ability to support a wide array of devices. It can accommodate a variety of sensors, keypads, and other peripherals, enabling users to customize their security systems to meet specific needs. The panel supports both hardwired and wireless devices, providing flexibility in installation and enhancing the overall adaptability of the security system.

Security is further enhanced through the XP-400's integration with Napco's proprietary technologies. The panel features built-in alarm verification, which significantly reduces false alarms by allowing for the confirmation of intrusion events before dispatching emergency services. This feature is critical for maintaining a good relationship with local authorities and ensures efficient utilization of resources.

Moreover, the XP-400 utilizes advanced communication technologies, supporting various forms of connectivity, including phone line, cellular, and internet-based connections. This multi-faceted communication strategy ensures that alerts and notifications are promptly delivered to users and monitoring centers, regardless of the circumstances.

In terms of user interface, the XP-400 is designed with ease of use in mind. The panel includes user-friendly keypads that allow for straightforward operation, programming, and user management. The intuitive layout ensures that even those with limited technical knowledge can navigate and manage their security system effectively.

Another notable characteristic of the XP-400 is its scalability. As security needs evolve, the panel can be expanded with additional zones and features, ensuring long-term viability and protection for its users. This scalability not only extends the life of the investment but also allows for future upgrades in response to changing security technologies and threat landscapes.

In conclusion, the Napco Security Technologies XP-400 stands out as a reliable and versatile security solution. With its advanced microprocessor, comprehensive device support, alarm verification, and flexible communication capabilities, it remains an excellent choice for those looking to enhance their security infrastructure. Its user-friendly design and scalability further solidify its reputation as a top-tier security panel on the market.