Napco Security Technologies XP-400 Specifications, Current & Voltage Ratings, Miscellaneous

Models: XP-400

1 28
Download 28 pages 54.33 Kb
Page 3
Image 3
Specifications

Specifications

Current & Voltage Ratings

Alarm Output --------------------------

Burg:

12 VDC, 2A (max.)

Output Current Limiting --------------

Burg:

2.25 A

 

AUX Power:

750 mA

Residential Burglary (4 Hour Standby)

 

Combined Standby Current:--------

350 mA

 

Bell Output: ----------------------------

2 A

 

(Using Rechargeable 12 VDC 4 AH BATTERY, minimal requirement)

Transformer and Battery

 

 

Required Transformer: --------------

NAPCO TRF12 OR

BASLER 16.5 VAC 20VA

 

 

Required Battery: ---------------------

12V 4 AH Rechargeable

Change Battery every 5 years or as required

 

Maximum Charging Current: ------

165 mA

 

Maximum Input Current:-------------

2.58 A

 

Loop Characteristics

Loop Voltage: --------------------------

5 Volts

 

Loop Current : --------------------------

Zones 1, 2:

0.9 mA (2.2 K)

 

Zones 3, 4:

0.5 mA (3.9 K)

Loop Resistance: ----------------------

100per zone (max.)

Device Specifications

Max # keypads: ------------------------

4, RPXP4GT current = 35 mA

Max # of receivers:--------------------

2, GEM-RECV-XP8

 

current = 65 mA each

Max Keypad wire length : ----------

1000’ total wire length

Miscellaneous

 

Housing Dimensions : --------------

105/16" x 86/16" x 3"

 

(26.2 x 21.3 x 7.6) HxWxD

Shipping Weight: ---------------------

XP-400/4 15.5 lbs.

Operating Temperature: -------------

0-49ºC (32-120°F)

3

Page 3
Image 3
Napco Security Technologies XP-400 Specifications, Current & Voltage Ratings, Transformer and Battery, Miscellaneous