Napco Security Technologies WI1370 XP-400Installation Instructions, 21Keypad Features

Models: XP-400

1 28
Download 28 pages 54.33 Kb
Page 14
Image 14
[21]Keypad Features 2

WI1370 XP-400 Installation Instructions

[21]Keypad Features 2

(1)Audible Panic - Keypad Panic will not turn the Bell on unless this option is programmed.

(2)Exit/Entry with Urgency - select to give an audible indication of Exit and Entry times. During the last 10 seconds of entry and exit time, the keypad sounds a distinct sound to indicate the premises must be left or the panel must be disarmed.

(3)Display Bypassed (Armed) - Select to display bypassed zones while the panel is armed.

(4)Disable Code Entry Beeps - Program to disable keypad beeping on valid code and function entries.

[22]Miscellaneous Features 1

(1)Abort Delay - Program to allow a 15 second Delay (except 24 Hour Zones) after a zone trip before reporting. Disarm the system within 15 seconds to prevent reporting.

(2)Easy Exit/Easy Arm - Enables A0

command. While the system is armed, entering this command allows 3 minutes to Exit through Exit/Entry and Exit/Entry Follower Zones. Enabling this option also

enables Easy Arm, enter a0 to arm the system.

(3)Swinger Shutdown - Automatically disables armed zones with excessive alarm/

restores (swingers). Non-24-Hour Protection zones: allows only 3 alarms and 2 restores per zone per arming before the zone is disabled.

(4)Bell on Line Cut (Armed) - Program to turn the Bell Output on if the telephone line has been cut while the panel is armed.

[23]Programmable Output Features 1

(1)Audio Verification - Program to activate the PGM during reporting. Select specific zones for audio verification by programming the required zones in PGM Output [08], PGM Features 2 [24] and PGM Features 3

[25].Connect the PGM to the VeriphoneTM trigger low input.

(2)Access Output - Activates the PGM output for 5 seconds using the A3

command.

(3)Follow Keypad Sounder - The following keypad sounds will activate the PGM output: Entry Sounder, Keypad Pulsing Sounder, Keypad Output on Alarm, Chime, Fault Find.

(4)Keyfob/Keyswitch Chirp - Program to chirp the PGM Output (1) one time when the panel is armed or (2) two times when the panel is disarmed. Wire as shown in Figure 6.

PGM

BLK

 

K1

+AUX

RED

 

 

 

COM

N/C

N/O

 

Siren Driver

+AUX

Steady Input

 

FIGURE 6 KEYFOB/KEYSWITCH CHIRP

[24]Programmable Output Features 2

(1)Reserved

(2)AUX - Program to activate the PGM on a AUX alarm.