Napco Security Technologies D D D X X X X X X X C, WI1370 XP-400Installation Instructions

Models: XP-400

1 28
Download 28 pages 54.33 Kb
Page 16
Image 16
[33]Receiver Options

WI1370 XP-400 Installation Instructions

000 033-1234

Leading Digits

Report Code

Subscriber ID Number

FIGURE 7 DEFAULT PAGER DISPLAY

Pager Alarm data is the same as 4/2 format with the exception that the 2 digit Report Code is transmitted before the 4 digit Subscriber ID.

[33]Receiver Options

(1)2300 Hz HS/Kissoff - Select 2300 Hz Handshake and Kissoff.

(2)Sumcheck - Only used for the following Receiver Formats: Ademco Slow, Radionics Fast, Silent Knight Fast and Universal High Speed. This is a sophisticated data format used to enhance the speed and check the accuracy of the received transmission. This format should be used whenever the central station has this capability. Instead of sending a second round to verify correct data, the panel sends a Sumcheck digit after sending the Subscriber ID and Alarm Code.

(3)Single Digit - 3/1 Format. 3-digit Subscriber ID number and a 1-digit Alarm Code will be transmitted.

(4)No Handshake/Pager Extend - The meaning of this option is dependent on Receiver Format programming.

No Handshake (All receiver formats except Pager

Format)

If programmed no Handshake is required.

Pager Extend (Pager Format Selected)

Pager PIN Number - Program if a PIN number is required by the paging system. The digits in Telephone Number 2 will be added on to telephone number 1 and/or telephone number 3 allowing for a total of 24 digits. See sample program below. Note: If selected do not program backup reporting.

If a 7-digit PIN number is required, program the panel as follows:

[31]- Pager Telephone number

[32]- Select Pager Format

[33] - Select Pager Extend

[41]- D D D X X X X X X X C 0

Delay

Leading 0

PIN Number

Terminating Digit (#)

Pager display will appear as shown in Figure 7 except there will be only one leading 0.

[34]Zone Report, Telco 1

Select zone(s) required to send an alarm report to Telephone Number 1.

[35]Zone Restore Report, Telco 1

Select zone(s) required to send a restore report to Telephone Number 1. The zones will send a restore after Bell time-out, unless programmed as silent zones.

[36]System Reporting, Telco 1

(1)Keypad Panic 2 - Program to activate a Keypad Panic 2 report (KK).

(2)AUX/AMBUSH - Program to activate an AUX or AMBUSH report (ff).

(3)Panic - Program to activate a Panic report (gG).

(4)Test Timer - Program to activate a Test Timer report.

16

Page 16
Image 16