Appendix A DESCRIPTION OF OPTIONAL EQUIPMENT

This appendix provides a brief description of op- tional equipment which can be connected to the FR-8051/8111/8251. For more detailed informa- tion, see the respective operator’s manual.

A.1 Performance Monitor

A performance monitor is required for a radar in- stalled on vessels of 300 GT and upward engaged in international voyages. For X-band radars, the FURUNO PM-30 satisfies the requirement cov- ering 9410 ±50 MHz.

The performance monitor is an independent unit, namely, it is not interconnected with any unit of the radar system except for the 100 VAC power cable. In some radars the power cable is not routed via the power switch or other control of the radar and the monitor is operated as completely a sepa- rate device.

Operating a performance monitor

Transmit the radar on the 24 nm range scale and select a long pulse. The radar screen will show several arcs, opposite to the heading marker (pro- vided that the performance monitor is installed behind the radar antenna as is normally the case.) If the radar transmitter and receiver are in good working conditions inasmuch as the original state when the monitor was tuned, the innermost arc should appear at 12 nm and there should be a to- tal of 4 arcs.

The range of the innermost arc reduces 3 nm with every 3 dB loss of transmitted power. The receiver sensitivity can be evaluated from the number of visible arcs; one arc is lost every 3 dB deteriora- tion of the sensitivity.

Transmitter

Receiver

performance

performance

 

 

 

 

Range to

Loss

No. of

Loss

innermost

 

arcs

 

arc

 

 

 

 

 

 

 

12 nm

0 dB

4

0 dB

 

 

 

 

9 nm

3 dB

3

3 dB

 

 

 

 

6 nm

6 dB

2

6 dB

 

 

 

 

3 nm or

10 dB

1

9 dB

less or none

 

 

 

 

 

 

 

 

 

0

12 dB

 

 

 

 

Display

Meaning

 

TRANSMITTER: normal

 

RECEIVER: normal

12 nm

 

TRANSMITTER: 3 db loss

 

(Transmitter system has lost

 

half of initial power.

9 nm

Suspect magnetron and

 

feeder system.)

 

RECEIVER: normal

 

TRANSMITTER: 3 db loss

 

(Transmitter system has lost

 

half of initial power.

9 nm

Suspect magnetron and

 

feeder system.)

 

RECEIVER: 3 db loss

 

(Receiver has lost half of

 

normal sensitivity. Suspect

 

receiver front end, water

 

leakage in feeder system,

 

etc.

A – 1

Page 60
Image 60