Display Unit
Picture tube |
| ||||||||||||
|
| Effective display diameter 180 mm |
|
|
|
|
| ||||||
Range (nm), Range ring interval (nm), Number of range rings |
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Range (nm) | 0.125 | 0.25 | 0.5 | 0.75 | 1.5 | 3 | 6 |
| 12 | 24 | 48 | 72 | 96 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ring intvl (nm) | 0.025 | 0.05 | 0.1 | 0.25 | 0.25 | 0.5 | 1 |
| 4 | 4 | 8 | 12 | 16 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
No. of rings | 5 | 5 | 5 | 3 | 3 | 6 | 6 |
| 6 | 6 | 6 | 6 | 6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
†Can be set to 1, 2, 4, 8, 16 or 32 nm when interfaced with video plotter. * Maximum ranges:
Minimum range | 25 m on 0.25 nm scale |
Range discrimination | 20 m on 0.75 nm scale |
Accuracy | Range: 1% of range in use or 8 m, whichever is the greater |
| Bearing: 1° |
Environmental Conditions | |
Standards | IEC 945 |
Ambient temperature | Antenna unit: |
| Display unit: |
Humidity | Relative humidity 95% at +40°C |
Waterproof test | Pressure 3.6 kg/cm2 (antenna unit) |
Power Supply and Power Consumption
12
100 V, 110 V, 115 V, 220 V, 230 VAC, 50/60 Hz, 1ø (rectifier required)
Others
Nav Data Input/Output Input (IEC 1162*) - - GP, LC, or any talker
BWC, DTP, GLL, GLC, HDG, MDA, RMA, RMB, RMC, VTG, DBK, DBS, DBT, GTD, HDM, HDT, MTW, BWR, VHW, ZDA
Output (IEC 1162) TLL, RSD, and TTM (w/ARP *:IEC 1162 is equivalent to NMEA0183, V2.0
Coating color | Antenna unit: Munsell N9.5 (white) |
|
|
| Display unit housing: 2.5GY5/1.5 (light gray) |
| |
| Panel: N3.0 (black) |
|
|
Compass safe distance | Standard compass | Steering compass | |
| Display unit | 1.3 m | 1.0 m |
| Antenna unit (C2P7N2N, 6 kW): | 3.4 m | 2.2 m |
| (C2P7N2N, 10 kW): | 3.8 m | 2.4 m |
| 4.3 m | 2.5 m |
xi