Furuno FR-8051 manual Problem Check point and probable Remedy Cause

Models: FR-8051

1 64
Download 64 pages 24.01 Kb
Page 53
Image 53

Problem

Check point and probable

Remedy

 

cause

 

 

 

 

 

 

Interference rejector

1. SPU Board

1.

Replace SPU Board.

inoperable

 

 

 

 

(interference rejection

 

 

 

 

level not displayed)

 

 

 

 

 

 

 

 

Echo Stretch

1. SPU Board

1.

Replace SPU Board.

ineffective (Neither

 

 

 

 

"ES1" nor "ES2" is

 

 

 

 

displayed.)

 

 

 

 

 

 

 

 

 

Only 2 parallel index

1.

Incorrect setting of index line

1.

Set index line interval referring to

lines (6 lines wanted)

 

interval

 

paragraph 1.18.

 

 

 

 

 

Range rings are not

1.

Press RINGS (PUSH)

1.

Replace associated circuit board if

displayed.

 

control to see if intensity is

 

unsuccessful.

 

 

increased.

2.

Replace control.

 

2.

Bad contact of control

3.

Replace SPU Board.

 

3.

SPU Board

 

 

 

 

 

 

Key beep inaudible

1. SPU Board

1.

Replace SPU Board.

 

 

 

 

 

Poor discrimination at

1.

Sea clutter control not

1.

Improper setting of A/C SEA effect

range

 

functioning properly.

 

is seen only at very close range.

 

 

 

 

Suspect inaccurate frequency of

 

 

 

 

crystal oscillator.

 

 

 

 

 

True Motion

1.

Poor contact of MODE key.

1.

Try to press MODE key a little

presentation not

2.

Selection is not accessed.

 

harder.

working correctly

3.

Speed entry is incorrect.

2.

Press MODE key until "TM"

 

4.

TM display inaccurate

 

appears.

 

 

 

3.

Enter correct own ship speed

 

 

 

 

referring to paragraph 1.23.

 

 

 

4.

Make sure that speed and compass

 

 

 

 

inputs are accurate.

 

 

 

 

Target not tracked

1. Poor definition of targets in

1.

Adjust A/C SEA and A/C RAIN

correctly

 

sea clutter

 

controls referring to paragraphs

 

 

 

 

1.11 and 1.12.

 

 

 

 

 

4 – 4