3.7 Suppressing Interference

Interference from other acoustic equipment operating nearby or other electronic equipment may show itself on the display as de- picted in the figure below.

Electrical equipment

Video sounder

Noise limiter on

interference

interference

 

Figure 3-15 How the noise limiter function works

To suppress interference, do the following:

1)Press the [MENU ESC] key.

2)Press the [6] key to display VIDEO SOUNDER SETUP menu.

3)Press the [] or [] key to select NOISE LM.

4)Press the [t] or [s] key to select degree of suppression de- sired; the higher the number the greater the degree of suppres- sion..

5)Press the [MENU ESC] key.

3.8Knowing Depth Change by Depth Alert Alarm

The DEPTH ALert function alerts you to change in depth. Depth change direction is given by alarm interval; the longer the interval the greater the change in depth.

To turn on or off the depth alert, do the following:

1)Press the [MENU ESC] key.

2)Press [6] key to display VIDEO SOUNDER SETUP menu.

3)Press the [] or [] key to select DEPTH AL.

4)Press the [t] or [s] to select ON or OFF.

5)Press the [MENU ESC] key.