DIMENSIONS AND SPECIFICATIONS

DIMENSIONS AND SPECIFICATIONS

Model #

 

Dimensions: In. (mm)

No. Of

Total BTU*

Gas Broiling Grid: In. (mm)

Width

 

Depth

Height

Burners

Natural

Propane

Width

Depth

 

 

 

 

 

 

 

 

 

 

 

 

HEEE-24CL

24(610)

 

37-1/4(946)

17-13/16(453)

4

54,000

50,000

20-1/8 (511)

23-1/2(597)

 

 

 

 

 

 

 

 

 

 

HEEE-36CL

34(864)

 

37-1/4(946)

17-13/16(453)

6

70,000

72,000

30-1/8(765)

23-1/2(597)

 

 

 

 

 

 

 

 

 

 

HEEE-48CL

48(1219)

 

37-1/4(946)

17-13/16(453)

9

105,000

105,000

44-1/8(1121)

23-1/2(597)

HEEE-60CL

58(1473)

 

37-1/4(946)

17-13/16(453)

11

115,000

138,000

54-1/8(1375)

23-1/2(597)

 

 

 

 

 

 

 

 

 

 

*Manifold operating pressure as per table shown below Gas Manifold 3/4" NPT on all model

Garland/U..S.. Range products are not approved or authorized for home or residential use, but are intended for commercial applications only..

Garland / U..S.. Range will not provide service, warranty, maintenance, or support of any kind other than in commercial applications..

Many local codes exist and it is the responsibility of the owner and installer to comply with those codes..

 

Manifold Operating Pressure

Minimum Supply Pressure

Models

Natural Gas

Propane

Natural Gas

Propane

 

 

 

 

 

 

"w..c(Mbar)

"w..c..(Mbar)

"w..c..(Mbar)

"w..c..(Mbar)

All Models

4..0(10)

10..0(25)

5..0(12..5)

11(27..5)

SHIPPING

INFORMATION

MODEL

Weight

Lbs/Kg

 

 

 

HEEE-24CL

338/153

 

 

HEEE-36CL

391/177

 

 

HEEE-48CL

505/229

 

 

HEEE-60CL

620/281

"w..c(Mbar) ELECTRIC CORD CONNECTION

38.75"

[978mm]

35.30"

[897mm]

Width Measurements In (mm)

Model

A

B

C

HEEE-24CL

14..28 (363)

23..50 (597)

24..00 (610)

 

 

 

 

HEEE-36CL

24..38 (721)

33..50 (851)

34..00 (864)

 

 

 

 

HEEE-48CL

38..28 (972)

47..50 (1206)

48..00 (1219)

HEEE-60CL

48..28 (1226)

57..50 (1460)

58..00 (1473)

 

 

 

 

Electrical : 120V, 60 Hz 15 Amp

Supplied with NEMA 5-15 P Power Cord

NOTE: Wiring Diagram is located in right side of broiler’s leg section..

.91"

[23mm]

 

8.47"

 

[215mm]

 

4.61"

A

[112mm]

 

B

 

C

 

37.25"

[946mm]

 

17.84"

 

[453mm]

 

14.58"

 

[370mm]

28.71"

1.50"

[729mm]

[38mm]

38.75"

 

[984mm]

 

Page 4

Part # 4522970 Rev 1 (10/28/09)

Page 4
Image 4