2.4.12Special Option -- Second Bonus Port (Models 1016 and 1024)

Magnum 1000 Workgroup Hubs

Installation and User Guide (04/02)

2.4.12Special Option -- Second Bonus Port (Models 1016 and 1024)

In special cases, it may be desirable to configure the Magnum 1016 or 1024 Workgroup Hub with a second Port Module. The 1016 and 1024 Workgroup Hubs were designed to accommodate such a configuration, and the second Bonus Port may be configured by a trained technician and connected into header J1-RPM. In order to install a second PM, it is necessary to replace the factory-installed Basic AUI Port, connected into header J1, with the desired Port Module. This procedure requires a Port Module connector cable (ordered separately as part number PM-CBL, or equal), and is similar that of the Model 1008 change from a Basic AUI to a PM. Request special quote for factory installation of a second Port Module for Models 1016 and 1024.

NOTE: LEDs of the 2nd PM (connected in J1-RPM) may not be functional.

NOTE: Due to the Bridge Port Module functionality, only one BPM may be configured per Workgroup Hub.