1.0SPECIFICATIONS

Magnum 1000 Workgroup Hubs

Installation and User Guide (04/02)

1.0SPECIFICATIONS

1.1Technical Specifications

Performance

Data Rate: 10Mbits / sec

Partitioning: Enforced after 32 consecutive collisions.

Reconnect: Occurs after 512 bits of error-free transmission.

Network Standards

Ethernet V1.0/V2.0 IEEE 802.3: 10BASE-T, 10BASE5, 10BASE2, 10BASE-FL & FOIRL.

(Magnum Workgroup Hubs are physical layer standard Ethernet products, and operate independently of all software.)

Maximum Ethernet Segment Lengths

 

 

DTE (AUI Drop Cable)

- 50 m (164 ft)

10BASE-T (twisted pair)

-

100 m (328 ft)

Shielded twisted pair

-

150m (492 ft)

10BASE2 ThinNet (BNC)

- 185 m (607 ft)

10BASE5 ThickNet

- 500 m (1,640 ft)

FOIRL multi-mode Fiber optic

-

1 km (3,281 ft)

10BASE-FL multi-mode Fiber optic

- 2 km (6,562 ft)

Single-mode Fiber optic

-

10 km (32,810 ft)

Connectors

TP : RJ-45 shielded, female

AUI: D-sub 15-pin female with slide lock

Other Media: via Port Modules

AC Power: IEC recessed male

Switches

Port 1, up-link switch for repeater-to-repeater connections.

LEDs

PWR (AC power on), ACT (common activity indicator), LINK (per port)

Operating Environment

Ambient Temperature: 32° to 120° F (0° to 50°C)

Storage Temperature: -5° to 140°F (-20°to 60°C)

Ambient Relative Humidity: 10% to 95% (non-condensing)

Packaging

Enclosure: High strength metal. Suitable for wiring closet shelf, desktop, or rack-mounting.

Dimensions: 1008: [8.5 x 7.75 x 1.75] in, [21.6 x 19.7 x 4.5] cm

1016 & 1024:[17.0 x 7.5 x 1.75] in, [43.2 x 19.1 x 4.5] cm

Weight: 1008: 3.4 lbs, 1.6 kg

1016: 3.1 lbs, 1.4 kg

1024: 3.3 lbs, 1.5 kg

Cooling method: Convection

www . GarrettCom . com

1

Page 7
Image 7
GarrettCom 1024 Magnum 1000 Workgroup Hubs, Installation and User Guide 04/02, Network Standards, Connectors, Switches