GarrettCom 1016, 1024, 1008 APPENDIX B Internal DC Power Supply Option, Magnum 1000 Workgroup Hubs

Models: 1016 1024 1008

1 44
Download 44 pages 29.81 Kb
Page 42
Image 42
APPENDIX B : Internal DC Power Supply Option
OPERATION
The -48VDC, 24VDC & 125VDC power option is designed using diodes inside on each DC power input line behind the two external power connection terminals,
so that the power from an externalHUB
SUPPLY

Magnum 1000 Workgroup Hubs

Installation and User Guide (04/02)

APPENDIX B : Internal DC Power Supply Option

B1.0 SPECIFICATIONS - FOR MAGNUM 1000 WORKGROUP HUBS

Power Supply (Internal -48 VDC Option)

DC Power Connector: 3 terminals: -“, “GND”, “+”

Input Voltage: 36 - 70 VDC (auto-ranging)

Power Consumption: Magnum 1000’s Hubs: 10 watts typical, 20 watts max. P.S. rating

Power Supply (Internal 24 VDC Option)

DC Power Connector: 3 terminals: -“, “GND”, “+”

Input Voltage: 20 - 40 VDC (auto-ranging)

Power Consumption: Magnum 1000’s Hubs: 10 watts typical, 20 watts max. P.S. rating

Power Supply (Internal 125 VDC Option)

DC Power Connector: 3 terminals: -“, “GND”, “+”

Input Voltage: 120 - 160 VDC (auto-ranging)

Power Consumption: Magnum 1000’s Hubs: 10 watts typical,

20 watts max. P.S. rating

With the exception of the power supply, all specifications and functions of Magnum 1000 Workgroup Hubs-48VDC, 24VDC & 125VDC models are identical to those listed in the main manual.

B2.0 -48VDC, 24VDC & 125VDC POWER OPTION, THEORY OF

source can only flow into the hub. This

A+

+

 

-

FUSE

allows the hub to operate only

A-

 

 

 

 

 

whenever DC power is correctly

GND

CHASSIS

GND

 

 

applied to the two inputs. It protects

 

 

the hub from incorrect DC input connections. An incorrect polarity connection, for example, will neither effect the hub, nor its power supply internally, nor will it blow the fuse in the internal power supply.

Disconnecting the power source is used for powering the hub on and off when it is placed into or taken out of service.

www . GarrettCom . com

36

Page 42
Image 42
GarrettCom 1016 APPENDIX B Internal DC Power Supply Option, Magnum 1000 Workgroup Hubs, Installation and User Guide 04/02