GarrettCom 1008 Magnum 1000 Workgroup Hubs, Installation and User Guide 04/02, Warranty, RPM Type

Models: 1016 1024 1008

1 44
Download 44 pages 29.81 Kb
Page 8
Image 8
Power Supply (Internal)

Magnum 1000 Workgroup Hubs

Installation and User Guide (04/02)

Power Supply (Internal)

AC Power Connector: IEC-type, male recessed, rear of chassis

Input Voltage: 90 to 260 VAC (auto-ranging)

Input Frequency: 47 to 63 Hz (auto-ranging)

Power Consumption: 10 watts typical, 20 watts max. P.S. rating

(For 48VDC power input option, see Appendix B).

Agency Approvals

UL Listed (UL 1950), cUL, CE

Emissions meet FCC Part 15 Class A

Warranty

 

Three years, return to factory

Made in USA

1.2Specifications - Repeater Port Modules (RPMs)

RPM Type :

BNC

AUI

DTE

Fiber-mm Fiber-sgl.m

TP*

Front Access

yes

yes

yes

yes

yes

yes

Connector Type

BNC-f

DB-15 f

DB-15 m

Fiber-ST Fiber-ST

RJ-45

Partition (PART)LED

yes

yes

yes

yes

yes

yes

Receive (RX) LED

yes

yes

yes

yes

yes

yes

LINK LED

n.a.

n.a.

n.a.

yes

yes

yes

Switch on Face Plate

yes**

n.a.

n.a.

n.a.

n.a.

 

yes***

“Fiber-mm” is multi-mode cable, normally used for 10BASE-FL installations, up to 2.0Km.

“Fiber-sgl.m” is single-mode cable, used for distant installations, up to 10.0Km.

*The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring.

**Internal termination switch for BNC, no "T" connector is required.

***MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 up-link, no crossover cable is required.

1.3Specifications - Bridge Port Modules (BPMs)

BPM Type :

BNC

AUI

Fiber

TP*

Connector Type

BNC(f)

DB-15(f)

ST

RJ-45

Switch on FP

yes**

n.a.

n.a.

yes***

FWD-I LED

yes

yes

yes

yes

FWD-X LED

yes

yes

yes

yes

LINK LED

n.a.

n.a.

yes

yes

*The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring.

**Internal termination switch for BNC, no "T" connector is required.

***MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 up-link, no crossover cable is required.

www . GarrettCom . com

2

Page 8
Image 8
GarrettCom 1008 Magnum 1000 Workgroup Hubs, Installation and User Guide 04/02, Power Supply Internal, Warranty, RPM Type