CHAPTER 2 - Installation
Preparing for Installation
2.1.3 Wiring and Grounding Guidelines
The DX40 requires several different types of connectors, cables, and wires. Requirements and recommendations are listed below:
Fiber | The fiber cables connected to the DX40 must be: |
| • |
| or |
| • |
| Technologies General Recommendation |
| standard |
| and |
| • terminated with LC connectors (see Section 1.3.3.) |
Grounding | The primary ground stud located on the top of the chassis must |
| be used to connect to an approved ground with a wire meeting |
| the following criteria: |
| • 14 AWG (minimum) |
| • a maximum of five feet in length |
| • terminated on the ground lug side with a #6 ring lug |
Facility Power The facility power cabling attached to the DX40 chassis must
| meet the following criteria: |
| • cabling constructed using 14 AWG stranded wire |
| • cable firmly attached to the terminal holes of the |
| |
| • cable routed and strain relieved to the chassis according to |
| good wiring practices |
Copper | Copper I/O cables and connectors must be shielded. |
DX40 Serial Device Router Installation Guide