CHAPTER 2 - Installation

Preparing for Installation

2.1.3 Wiring and Grounding Guidelines

The DX40 requires several different types of connectors, cables, and wires. Requirements and recommendations are listed below:

Fiber

The fiber cables connected to the DX40 must be:

 

non-dispersion shifted, single mode (SM)

 

or

 

multi-mode (MM) fiber cables defined by the Telcordia

 

Technologies General Recommendation 20-CORE

 

standard

 

and

 

• terminated with LC connectors (see Section 1.3.3.)

Grounding

The primary ground stud located on the top of the chassis must

 

be used to connect to an approved ground with a wire meeting

 

the following criteria:

 

• 14 AWG (minimum)

 

• a maximum of five feet in length

 

• terminated on the ground lug side with a #6 ring lug

Facility Power The facility power cabling attached to the DX40 chassis must

 

meet the following criteria:

 

• cabling constructed using 14 AWG stranded wire

 

• cable firmly attached to the terminal holes of the

 

non-polarized power unit, as illustrated in Figure 2-7.

 

• cable routed and strain relieved to the chassis according to

 

good wiring practices

Copper

Copper I/O cables and connectors must be shielded.

DX40 Serial Device Router Installation Guide

10

Page 22
Image 22