Troubleshooting

LED status

 

 

 

 

 

 

 

 

Power LED

Lamp LED

Problem

Possible Cause

 

 

 

 

 

Flashing orange

Red

Fan On error

The fan is not running.

 

 

 

 

 

Green

Orange

Lamp Case Open

The lamp access panel is

 

 

error

closed.

 

 

 

 

 

Orange

Orange

Lamp On error

The lamp is not on.

 

 

 

 

 

Orange

Flashing orange

Lamp Time Over

The lamp module has been in

 

 

error

operation between 1400 hours

 

 

 

and 1500 hours.

 

 

 

 

 

Red

Orange

Lamp Time Over

The Lamp module has been in

 

 

error

operation over 1500 hours.

 

 

 

Replace lamp module.

 

 

 

 

 

Orange

Flashing red

Temperature error

The lamp temperature is

 

 

 

between 161.6°F (72°C) and

 

 

 

165.2°F (74°C).

 

 

 

 

 

Red

Red

Temperature error

The lamp temperature is over

 

 

 

165.2°F (74°C). Turn off the

 

 

 

projector immediately.

 

 

 

 

 

On-screen status messages

No signal

Projector is searching for a video input source.

Out of range

You are too far away from the projector for the remote to function correctly.

Replace the lamp!

The lamp module has been in operation for more than 1500 hours. For information on replacing the lamp module, see “Changing the lamp module” on page 27.