10Insert the new PCI card into the riser card, making sure any connectors extend through the slot at the back of the assembly and that the card is fully seated in the riser card.
11Close the lock to hold the card in place, then replace the screw that holds the lock closed.
12Position the PCI riser assembly over the PCI sockets on the server board, Then press the PCI riser assembly into the PCI sockets.
13Follow the instructions in “Closing the server case” on page 30.
14See the card’s documentation for software installation instructions.
Replacing system fans
This server contains six groups of
To replace a fan group:
1Follow the instructions in “Preventing static electricity discharge” on page 28.
2Follow the instructions in “Opening the server case” on page 29.
System fan location
3Note which fan group is not working and therefore needs to be replaced.
Important
Make sure that the arrows on top of the fans indicating airflow point to the back of the chassis. The fan cable should exit the fan module toward the back of the chassis.
4Disconnect the
5Lift the fan group from the fan cage in the chassis.
6Insert the replacement fan group into the fan cage.
7Connect the
8Follow the instructions in “Closing the server case” on page 30.
41