CHAPTER 4: Installing Components
To replace the system fans and the fan board:
1Follow the instructions in “Preventing static electricity discharge” on page 28. Make sure that you turn off the server, then unplug the power cord(s) and all other cables connected to the server.
2Follow the instructions in “Opening the server case” on page 29.
3Disconnect the
4Lift the fan cage and fans (1) out of the server.
5Push the fan board lock (2) toward the back of the server case to release the fan board.
6Push the fan board toward the fan board lock to disengage it from the locking tabs (3), then lift the fan board out of the server case.
7Insert the replacement fan board into the server case, aligning the locking slots in the board with the locking tabs in the case.
8Push the fan board away from the fan board lock, then move the lock into position to hold the fan board in place.
9Place the system fan cage and fans onto the fan board, making sure to engage the fan cage with the locking tabs on the chassis.
Important
Make sure that the arrows on top of the fans indicating airflow point to the back of the chassis. The fan cable should exit the fan module toward the back of the chassis.