Assigning RAID Levels
Only one RAID level can be assigned to each logical drive. The drives required per RAID level is:
RAID | Minimum Number of | Maximum Number of Physical |
| |
Level |
| Physical Drives | Drives |
|
0 |
| One | 32 |
|
1 |
| Two | Two |
|
3 |
| Three | Eight |
|
5 |
| Three | Eight |
|
10 |
| four | Eight |
|
30 |
| Six | 32 |
|
50 |
| Six | 32 |
|
|
|
|
|
|
Configuring Logical Drives
Step
1
2
3
4
5
6
7
After you have installed the ADAC Ultra2 S466 controller in the server and have attached all physical disk drives, perform the following actions to prepare a RAID disk array:
Action
Optimize the ADAC Ultra2 S466 controller options for your system. See Chapter 6 for additional information.
Perform a
Press <Ctrl> <M> to run the ADAC Configuration Manager.
Define and configure one or more logical drives. Select Easy Configuration in ADAC Configuration Manager or select New Configuration to customize the RAID array.
Create and configure one or more system drives (logical drives). Select the RAID level, cache policy, read policy, and write policy.
Save the configuration.
Initialize the system drives. After initialization, you can install the operating system.
48ADAC Ultra2 S466 Hardware Guide