Planning the Array Configuration

Answer the following questions about this array:

Question

Answer

Number of physical disk drives in the array

Purpose of this array. Rank the following factors:

Maximize drive capacity

Maximize the safety of the data (fault tolerance)

Maximize hard drive performance and throughput

How many hot spares?

Amount of cache memory installed on ADAC Ultra2 S466

Are all of the disk drives and the server protected by a UPS?

Using the Array Configuration Planner The following table lists the possible RAID levels, fault tolerance, and effective capacity for all possible drive configurations for an array consisting of one to eight drives. This table does not take into account any hot spare (standby) drives. You should always have a hot spare drive in case of drive failure. RAID 1 and RAID 10 require 2, 4, 6, or 8 drives. RAID 30 and RAID 50 require at least 6 drives.

50ADAC Ultra2 S466 Hardware Guide