GE 1908 - 36 manual Before Delivery, Ventilation, Clearances to combustible construction

Models: 1908 - 36

1 52
Download 52 pages 4.01 Kb
Page 17
Image 17
BEFORE DELIVERY

BEFORE DELIVERY

Safety requirements

 

 

BEFORE DELIVERY

In order to be able to install your appliance as soon as it is delivered, you will have to check that the layout of your kitchen and your gas and electricity supplies are ready for it.

All gas and electrical installations must comply with the standards and current regulations, as well as with the requirements of local gas and electricity suppliers.

In the event of the appliance being installed by us, our technicians may ask you for a certificate proving that your domestic installation is compliant.

The manufacturer shall not incur any liability for an incorrect installation, and incorrect installa- tions shall void the warranty. Moreover, no legal actions can be undertaken in relation to incorrect installations.

1.SAFETY REQUIREMENTS

1.1. Ventilation

Special care should be taken to respect the regulation in force regarding ventilation. All requi- rements and regulations in force regarding the ventilation of rooms where gas appliances are installed should be respected.

The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is installed. It is essential that the kitchen where the "La Cornue" stove will be installed has excellent ventilation to the outside, for vapor and combustion gases, and a fresh air inlet.

Do not use air recycling systems.

Ventilation exhaust devices can be vapor aspirators or hoods.

The ventilation hood has to be built with non combustible material.

1.2. Clearances to combustible construction

Fig. 1 on the next page shows the minimum recommended distances and clearances from the range to near’by surfaces.

You must provide adequate clearances between the range and adjacent combustible surfaces. These dimensions must be met for safe use of your range.

The minimum horizontal distance from sides of appliance to the adjacent vertical combustible walls extending 18" (457 mm) above the top panel is 12" (305 mm).

The maximum depth of overhead cabinets is 13" (330 mm).

The minimum horizontal distances between overhead cabinets is not less than the nominal width of the appliance 36" (914 mm).

Installation and User Guide CornuFé 1908 - 36" - USA / Can

15

08NOTINSTALFE8/USA-1

Page 17
Image 17
GE 1908 - 36 manual Before Delivery, Ventilation, Clearances to combustible construction