Installation Instructions

230/208 VOLT ELECTRICAL CONNECTION OPTIONS
HOW TO CONNECT

1.Remove the room cabinet.

2.Connect to electrical power.

3.Review the following steps for applicable supply voltages.

4.Reinstall the room cabinet.

Power cords may include an arc fault interruption or a leakage current detection interruption device. A test and reset button is provided on the plug case or the inline case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the Zoneline and contact a qualified service technician.

POWER CORDCONNECTION

A powersupply kit withLCDI must be usedto supplypower to the Zonelineunit.Theappropriatekit is determinedby the voltage, the means of electricalconnectionand

the amperage of the branch circuit.

Appearance may vary.

Power supply kit

Connectionsof 208 or 230-voltcircuits may be with a power supplykit or a junction box kit.

All wiring, including installation of the receptacle, must be in accordance with the NEC and local codes, ordinances and regulations. Codes require the use of an arc fault or leakage current detection device on the power cord except direct connect. Be sure to select the correct cord for your installation.

Tandem

Perpendicular

Large Tandem

15 Amp.

20 Amp.

 

30 Amp.

230/208-volt receptacle configuration.

 

 

 

 

Branch Circuit and

 

Proper GE Power Cord
Unit AmperageRating

 

 

with LCDIDevice

 

 

 

 

 

 

 

15

 

 

RAK3153

 

 

 

 

 

 

 

20

 

 

RAK3203

 

 

 

 

 

 

 

30

 

 

RAK3303*

 

 

 

 

 

 

*Not approved for use on 7000 BTU models.

ELECTRICAL SUBBASE

CONNECTION

230/208-volt models may be installed using one of the following electrical subbases:

Branch CircuitandProper GE

UnitAmperage Rating

Subbase Kit

 

 

 

15

RAK204D15P

 

 

 

20

RAK204D20P

 

 

 

30

RAK204D30P*

 

 

 

*Not approvedfor use on 7000 BTUmodels.

Electrical subbases provide an enclosurefor direct connection or enclosed receptacles. The subbase kit includes the power cord.

The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes.

DIRECT CONNECTION

Order the following Kit for 230/208-volt direct connection as required:

Branch Circuitand

Power SupplyPower

UnitAmperage Rating

Accessory

Supply Kit

 

 

 

 

15

RAK4002A

RAK4157

 

 

 

 

20

RAK4002A

RAK4207

 

 

 

 

30

RAK4002A

RAK4307*

 

 

 

 

*Not approved for use on 7000 BTU models.

Skip to the “MAKE ELECTRICAL CONNECTION TO THE UNIT” section.

13