Care and cleaning.Room Cabinet and Case

Turn the Zoneline off and disconnect the

To clean, use water and a mild detergent.

power supply.

Do not use bleach or abrasives. Some commercial

 

cleaners may damage the plastic parts.

Outdoor Coils

The coils on the outdoor side of the Zoneline should be checked regularly. If they are clogged with dirt or soot, they may be professionally steam cleaned. Youwill need to remove the unit from the wall sleeve to inspect the coils. The dirt buildupoccurs on the fan side of the outdoor coil.

Coils

Grille

Clean the outside coils regularly.

Base Pan

In some installations, dirt or other debris may be

In some areas of the United States, a naturally

blown into the unit from the outside and settle in

occurring “gel-like” or “slime-like”substance may

the base pan (the bottom of the unit).

be seenin the base pan.

 

Check it periodically and clean, if necessary.

Instructions Safety

Instructions Operating

Cleaning and Care

Ventilation Filter

If the vent door is open, access requires the removal of the unit fromthe wall sleeve.Cleanthe ventfilter twicea year or as required.

Turnthe Zoneline off and unplugbefore cleaning.

To clean the ventfilter:

IMPORTANT:

This filter is not removable. Trying to remove this filter will damage the unit.

Use a vacuum to remove debris fromthe filter.

Use a damp rag to wipe down the filter and surrounding area after vacuuming.

Tips Troubleshooting

Remove two shipping screws (if operation is desired)