About the controls on yourZoneline.

GEAppliances.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMP CONTROL FAN,MODE & SLEEPOPERATION

Controls

Instructions SafetyInstructions Operating
Temp Control

The temp control is used to maintainthe room temperature. The compressor willcycle on and off to keep the roomat the same level of comfort.

Pressthepad to raise the temperature. Pressthepad to lowerthe temperature.

NOTE: The displayshows the set temperature, not the room temperature.

Sleep

Press to set the air conditionerto run for 8 hours before it automatically returnsto the previous setting.

When in the cooling mode and the sleep timer is set, the set temperature will automatically increase 2°F after the second hour then 1°F each hour over the next two hours. Also, the fan speed will change to low. When in the heating mode, the set temperature will decrease in the same manner.

To cancel the sleep mode, press the MODE pad or the SLEEP pad a second time.

Fan, Mode and Operation Control

FAN—Sets the fan operation for HIGH, LOW or AUTO speed. When set at AUTO, it automatically switches between LOW and HIGH as room temperature changes.

MODE—COOL—For cooling

FAN—For fan-only operation

HEAT—For heating

OPERATION—ON/STOP—Turns the unit on or off.Power remains connected to the Zoneline. The Freeze/Heat Sentinel features still functionif active.See the Freezer/Heat Sentinel section on page 6.

NOTE:The temperature display will flash to indicate a possible unit malfunction. Set operation control to STOP and then restart the unit. If the flashing light reappears within 30 minutes, call for service.

Quick Heat Recovery

Activates each time the thermostat is switched from STOP or COOL modeto HEATmode. Electric heaters are energizeduntil the thermostat set point

is reached. On heat pump models, the heat pump operation will resume at the next call for heat.

Cleaning and CareTips Troubleshooting
AboutYour Heat Pump (6100Series only)

Heat pumps can savemoney by removing heat from the outside air—even when the outside temperatureis below freezing—and releasing that heat indoors.

To get the best performance from your heat pump, don’tchangethe room thermostat very often. Raising the heat setting 2–3 degrees will cause the Zoneline to use its electric heating elements in order to reach the new temperature settingquickly.

There is a 3-minute minimum compressor

run time at any setting to prevent short cycling.

The indoor fan motor starts beforethe compressor and stops after the compressor cycles off.

When the outdoor temperature is lower than 25°F, heat is provided by the electric heater in the air conditioner instead of by the heat pump.

The electric heating elements use much

 

moreelectricity than heat pumps and cost

3

moreto operate.