6INSTALL THE AIR CONDITIONER

Installation Instructions

5 PREPARE THE WINDOW AND INSTALL

THE CASE (continues)

H

CAUTION:

 

 

To prevent broken

Vinyl

 

glass or damage to

 

 

windows, on vinyl or

 

 

other similarly

 

 

constructed windows,

 

 

attach the window

 

 

locking bracket to the window side jamb.

 

Attach the window locking

Wood

 

bracket with one Type C

 

 

 

screw..

 

ICut the foam top window gasket to the

window width.

J Stuff the foam between the

glass and the window to

prevent air and IN THE CASE (continues)Manual background insects from getting into the room. NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.

6INSTALL THE AIR CONDITIONER

IN THE CASE

ASlide the air conditioner into the case by the base pan. Do not push on the controls, styrofoam air discharge housing or the finned coils. Make sure the air conditioner is firmly seated.

Do not press on these areas— damage to the unit may result

Base Pan

6INSTALL THE AIR CONDITIONER

IN THE CASE (continues)

BReplace the 2 screws removed earlier, one on each side of the case.

IMPORTANT: THE GROUND SCREWS MUST BE REINSTALLED TO ENSURE PROPER GOUND.

CReinstall the control to the panel housing by replacing the 2 screws you removed earlier.

Install Screws

DAttach the front grille to the case by inserting the tabs on the grille into the slots on the front top of the case. Push the grille in.

EReplace the screws.

FInstall the filter and the front grille.

GPlug in the air conditioner.