GE Cool Only Installation Instructions, Air Conditioner, Before You Begin

Models: AJCH 08 ACB, AJCH 10 ACB, AJCH 10 DCB, AJCH 12 DCB, AJCQ 06 LCB, AJCQ 08 ACB, AJCQ 10 ACB, AJCQ 10 DCB, AJCQ 12 DCB, AJCS 06 LCB, AJCS 08 ACB, AJCS 10 ACB, AJCS 09 DCB, AJCS 10 DCB, AJCS 12 DCB, AJEH 12 DCB, AJES 06 LSB, AJES 08 ASB, AJES 09 DCB, AJES 10 AJCH 08 ACB, AJCH 10 ACB, AJCH 10 DCB, AJCH 12 DCB, AJOQ 06 LCB, AJOQ 08 ACB, AJOQ 10 ACB, AJOQ 10 DCB, AJOQ 12 DCB, AJGS 06 LGB, AJGS 08 ACB, AJGS 10 ACB, AJGS 09 DCB, AJGS 10 DCB, AJGS 12 DCB, AJEH 12 DCB, AJES 06 LSB, AJES 08 ASB, AJES 09 DGB, AJES 10 Cool Only

1 76
Download 76 pages 480 b
Page 12
Image 12
Installation Instructions

Installation Instructions

Air Conditioner

Air ConditionerQuestions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT Save these instructions for local inspector’s use.

IMPORTANT Observe all governing codes and ordinances.

Note to Installer – Be sure to leave these instructions with the Consumer.

Note to Consumer – Keep these instructions for future reference.

Skill level – Installation of this appliance requires basic mechanical skills.

Completion time – Approximately 1 hour

We recommend that two people install this product.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

BEFORE YOU BEGIN ELECTRICAL REQUIREMENTS

Some models require a 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

 ELECTRICAL REQUIREMENTSCAUTION:

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems—consult a qualified electrician.

IMPORTANT!

GE strongly recommends the removal of the old wall case and the installation of a new GE Wall Case. If you decide to keep the existing wall case, you may need a kit to ensure proper performance. If you DO NOT use a kit, you run the risk of poor performance or product failure. This is not covered under the terms of the GE warranty.

J-MODEL QUALIFYING QUESTIONS

J-model air conditioners may fit in existing wall cases. However, they often need a kit to properly adapt the case to the GE air conditioner. Answer these questions and see the chart on the next page for the proper kit.

AWhat brand air conditioner will you be replacing?

BWhat are the dimensions of the wall case currently in use?

CWhat is the model number of the chassis currently in use? What is the model (or Type) number of the wall case currently in use?

Frequently, the J-model adapter kit will apply to another brand model “series” or specific vintage. In these cases, you need the chassis model number and/or the wall case or “type” number to confirm the use of the correct adapter kit.

DWhat type of outdoor grille is used with the current wall case?

There may be an architectural grille attached to a wall case to enhance the exterior appearance of the building. Custom grilles may be used with J-model wall cases provided a J-model adapter kit is also used to ensure proper airflow.

12

Page 12
Image 12
GE Cool Only Installation Instructions, Air Conditioner, Before You Begin, Electrical Requirements