2. Muminum Wiring
A. Connect length of copper building wire to range terminal block.
B. Splice copper wires to aluminum wiring using special connectors designed and U.L. approved for joining copper to aluminum, and follow the connector manufacturer’s recommended procedure closely.
NOTE: Wire used, location and enclosure of splices, etc., must conform to good wiring practice and local codes.
STEP 5
4*IRE SYSTEM
SPECIAL GROUNDING INSTRUCTIONS
WARNING:
Frame grounded to neutral of appliance through a link. If used in a MOBILE HOME or if LOCAL CODES do not permit grounding through the neutral:
1)disconnect the link from neutral,
2)use grounding terminal or lead to ground unit in accordance with local codes, and
3)connect neutral terminal or lead to branch circuit in usual manner.
(If the appliance is to be connected by means of a cord set, use
/
CONNECTOR |
| |
BLOCK |
| |
4TH GROUNDI | GROUND | |
LUG | ||
|
STEP 6
ANTI-TIP BRACKET INSTALLATION
AN
1beginning installation.
WARNING
1.Range must be secured by
2.See instructions to install (supplied with bracket).
3.Unless properly installed, range could be tipped by stepping or sitting on door. Injury might result from spilled hot liquids or from range itseti.
Typical installation of
Attachment to Wall
Bracket |
|
Screw Must Enter | Wall Plate |
Wood or Metal k | I |
h, |
STEP 7
LEVELING THE RANGE
The range must be leveled. Leveling feet are located on each corner of the base of the range. Remove the storage drawer and rotate the leveling feet in or out as required. To remove drawer, pull it out all the way, tilt up the front and remove it. To replace, insert glides at back of drawer beyond stop on range glides. Lift drawer if necessary to insert easily.
One of the rear leveling feet will engage the ANTI- TIP bracket (allow for some side to side adjustment). Nlow a minimum clearance of 1/811 between the range and the leveling foot that is to be installed into the
Check the range for proper installation into the
STEP 8
FINAL CHECK
Be sure all switches are in the “off” position before leaving the range.
29