.-1WARNING: CONNE~OR BLOCK IS APPRO~D FOR COPPER ~RE CONNE~ON ONLY.

2. Muminum Wiring

A. Connect length of copper building wire to range terminal block.

B. Splice copper wires to aluminum wiring using special connectors designed and U.L. approved for joining copper to aluminum, and follow the connector manufacturer’s recommended procedure closely.

NOTE: Wire used, location and enclosure of splices, etc., must conform to good wiring practice and local codes.

STEP 5

4*IRE SYSTEM

SPECIAL GROUNDING INSTRUCTIONS

WARNING:

Frame grounded to neutral of appliance through a link. If used in a MOBILE HOME or if LOCAL CODES do not permit grounding through the neutral:

1)disconnect the link from neutral,

2)use grounding terminal or lead to ground unit in accordance with local codes, and

3)connect neutral terminal or lead to branch circuit in usual manner.

(If the appliance is to be connected by means of a cord set, use 4-conductor cord for this purpose.)

/

CONNECTOR

 

BLOCK

 

4TH GROUNDI

GROUND

LUG

 

STEP 6

ANTI-TIP BRACKET INSTALLATION

AN ANTI-TIP bracket is supplied with instructions for installation in a variety of locations. The instructions include a template, a parts list and a list of tools necessary to complete the installation. Read the IMPORT~T SAF~ INflRUCTIONS and the instructions that fit your situation before

1beginning installation.

WARNING

1.Range must be secured by ANTI-TIP bracket supplied.

2.See instructions to install (supplied with bracket).

3.Unless properly installed, range could be tipped by stepping or sitting on door. Injury might result from spilled hot liquids or from range itseti.

Typical installation of Anti-Tip bracket

Attachment to Wall

Bracket

 

Screw Must Enter

Wall Plate

Wood or Metal k

I

h,

STEP 7

LEVELING THE RANGE

The range must be leveled. Leveling feet are located on each corner of the base of the range. Remove the storage drawer and rotate the leveling feet in or out as required. To remove drawer, pull it out all the way, tilt up the front and remove it. To replace, insert glides at back of drawer beyond stop on range glides. Lift drawer if necessary to insert easily.

One of the rear leveling feet will engage the ANTI- TIP bracket (allow for some side to side adjustment). Nlow a minimum clearance of 1/811 between the range and the leveling foot that is to be installed into the ANTI-TIP bracket.

Check the range for proper installation into the ANTI-TIP bracket (after the range has been properly installed) by grasping the edges of the REAR burner holes and carefully attempting to tilt the range forward.

STEP 8

FINAL CHECK

Be sure all switches are in the “off” position before leaving the range.