Installation Instructions

A

Cutout for 27(68.6 cm) Single Built-In

Ovens only Under Counter

For JKS10, JKP30, JKP70, PK916, ZEK938 models only.

Gas or electric cooktops may be installed over this oven. See cooktop installation instructions for cutout size. See label on top of oven for approved cooktop models.

25(63.5 cm)

Top and/or side fillers may be necessary

if unit is positioned between existing cabinets. Be sure they are attached securely, since they will anchor the oven in the cabinet.

3/4(1.9 cm)

Support Platform

Required

25(63.5 cm) Min.

25 1/4(64.1cm) Max.

275/8(70.2 cm) Min.

281/8(71.4 cm) Max.

240V / 208V

 

 

Junction Box

 

5

Location

(12.7 cm)

Max. from the

 

left or right

 

 

side

 

 

 

Allow

1

(2.5 cm)

unit overlap top and bottom of oven, 1(2.5 cm) unit overlap side edges

Must match toekick height

Gas and electrical connections for gas cooktop must be located in an adjacent accessible location to the right.

22(55.9 cm) Min.

Above Support 36(91.4 cm)

PlatformTypical Countertop Height

24(61cm)

4(10.2 cm)

Typical

Toekick

MUST SUPPORT 150 LBS. (68 Kg)

NOTE: This oven is only approved to be installed under the specific models as labeled on this unit.

6

Page 6
Image 6