Cutout for 30″ (76.2 cm) Single Built-In Ovens only Under Counter

Installation Instructions

A

Cutout for 30(76.2 cm) Single Built-In Ovens only Under Counter

For JTP30, JTP70, PT916, PT920, ZET938 models only.

Gas or electric cooktops may be installed over this oven. See

 

 

 

 

 

cooktop installation instructions for cutout size. See label on

240V / 208V

 

 

 

top of oven for approved cooktop models.

 

 

 

Junction Box

 

 

 

 

 

 

 

 

 

 

Location (junction

 

 

 

 

 

box may be in

 

 

 

 

 

adjacent cabinet)

 

 

 

25

(63.5 cm)

 

9

1/2

Gas and electrical connections

 

 

 

 

 

 

 

(24.1 cm)

for gas cooktop must be located

 

 

 

in an adjacent accessible

 

 

 

Max.

 

 

 

location to the right.

 

 

 

 

 

 

 

 

 

 

 

 

Top and/or side fillers

 

 

 

 

 

 

 

 

 

 

may be necessary

 

 

 

 

 

 

 

 

 

 

if unit is positioned

 

 

 

 

 

 

 

 

 

 

between existing

 

28 1/2(72.4 cm) Min.

 

 

 

 

 

 

 

cabinets. Be sure

 

 

 

 

 

 

 

 

they are attached

 

28 5/8(72.7 cm) Max.

 

 

 

 

 

 

 

Allow 1(2.5 cm)

 

 

 

 

 

 

securely, since they

 

 

 

 

 

 

 

 

 

 

 

 

overlap top

 

 

 

 

36(91.4

cm)

will anchor the oven

 

 

 

 

22(55.9 cm) Min.

 

 

 

of oven,

 

in the cabinet.

 

 

 

 

Above Support

Typical

 

27 1/4(69.2 cm) Min.

 

11/16(1.8 cm)

 

Countertop

 

 

 

Platform

 

27 5/16(69.4 cm) Max.

overlap side edges

 

Height

 

 

 

 

 

 

 

 

 

of cutout and

 

 

 

 

 

 

 

 

 

 

1 1/4(3.2 cm)

 

 

 

 

 

 

 

 

 

 

overlap bottom

 

 

 

 

 

 

 

 

 

 

of oven.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24(61

cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4(10.2 cm)

 

 

Typical

3/4(1.9 cm)

 

Toekick

 

 

Support Platform

Must

 

Required

 

 

match

NOTE: This oven is only

 

toekick

 

approved to be installed under

 

height

 

 

the specific models as labeled

MUST SUPPORT 150 LBS. (68 Kg)

 

on this unit.

 

 

Side by Side Installations

Install two wall ovens in separate cutouts. Allow 2(5.1 cm) min. between cutouts.

Cutout –

Observe all dimensions and requirements.

2(5.1 cm)

Min.

Cutout –

Observe all dimensions and requirements.

11

Page 11
Image 11
GE r08654v-1 Cutout for 30″ 76.2 cm Single Built-In Ovens only Under Counter, Installation Instructions