Cutout for 30″ (76.2 cm) Single Built-In

Installation Instructions

A

Cutout for 30(76.2 cm) Single Built-In

Ovens only

For JTP30, JTP70, PT916, PT920, ZET938 models only.

 

Cutout

9 1/2(24.1 cm)

 

Width

Max.

Junction Box

 

28 1/2(72.4 cm)

 

Location

 

Min.

 

(junction box

 

28 5/8(72.7 cm)

 

may be

 

Max.

 

located in

 

 

 

adjacent

Allow 11/16

 

 

cabinet)

(1.75 cm) for

 

 

 

overlap of oven

 

 

 

over side edges

 

 

 

of cutout

Opening

Cutout

 

 

Between

 

 

Height

 

 

Inside Walls

 

 

27 1/4

22(55.9 cm)

 

Must Be

 

(69.2 cm) Min.

Min. to

 

At Least

 

27 5/16

Bottom of

 

28 1/2

 

(69.4 cm) Max.

Junction Box

 

(72.4 cm)

 

 

 

21

Wide

 

 

 

 

 

(53.3 cm)

 

 

 

 

 

Recommended

 

 

Allow 1(2.5 cm)

cutout location

 

 

minimum for

from floor 32 1/2

 

overlap of oven

(82.6 cm)

 

Cabinet Width

30(76.2 cm)

Recommended

 

 

Cutout Location

 

 

from Floor

32

1/2(82.6 cm)

Cutout Depth

23

1/2(59.7 cm) Min.

Cutout Width

28

1/2(72.4 cm) Min.

 

28

5/8(72.7 cm) Max.

Cutout Height

27

1/4(69.2 cm) Min.

 

27

5/16(69.4 cm) Max.

NOTE: If the cabinet does

not have a front frame and the sides are less than 3/4(1.9 cm) thick, shim both sides equally to establish the cutout width.

 

 

top and 114

 

Allow a minimum

of 21(53.3 cm) for

 

(3.2 cm) overlap

 

clearance to adjacent

 

of oven bottom

corners, drawers,

 

 

of cutout

walls, etc. when

 

 

Cabinet

 

door is open

 

Width

 

 

 

30

(76.2 cm)

If the cabinet does not have a solid bottom, two braces or runners must be installed level with the bottom of the cutout to support the weight of the oven. For single ovens, the runners and braces must support 150 lbs (68 Kg).

Suitable

Bracing to Support Runners

C

L

2x 4

(5 cm x 10 cm) or equivalent runners level with bottom of cutout

NOTE: If marks, blemishes or the cutout opening are visible above the installed oven, it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered.

215/8

(54.9 cm) Over

Centerline of Cabinet

Side by Side Installations

Install two wall ovens in separate cutouts. Allow 2(5.1 cm) min. between cutouts.

These ovens are not approved for stackable installations.

Cutout –

2(5.1 cm)

Observe all

Min.

dimensions

 

and

 

requirements.

 

 

 

Cutout –

Observe all dimensions and requirements.