JXRB57 Kit

For Indoor Remote Blower Locations

Step1

(continued)

Remove the 4 nuts holding the blower to the mounting plate. One nut is hidden inside the outlet. Remove blower.

Remove the blower mounting plate.

Remove 2 screws along the bottom of the blower box which are visible once blower plate is removed.

Carefully, turn the unit over to access the back side.

Remove 4 screws along the top of the blower box.

Turn unit over and remove the 4 screws along the top.

Remove the blower box.

Retain all screws.

Important: Save any unused parts. If the appliance is relocated at a later time, parts may be needed.

Hidden

Screws

Step2

Determine

Blower

Location

Blower Box

 

 

Blower

Blower

 

 

 

Mounting

 

 

 

Plate

 

 

 

 

 

 

 

• Determine location of the blower and

 

 

14-1/2"

 

 

 

 

 

 

 

 

 

 

 

 

motor.

 

 

 

 

 

 

 

 

 

 

The blower will fit between floor joists, 16” on center. Or, provide a surface to attach the entire assembly to the underside of the floor.

Secure mounting brackets to the top of the blower with screws and nuts. One bracket in each corner, as illustrated.

Set the bracket at the ends of the curved slots to reach a 14-1/2” span between floor joists, or adjust for your installation situation.

Mark the installation location and cut hole for 6” round duct.

• Secure the blower to the joists.