Ductwork

G a s Downdraf t Cooktop

Duct Fittings

Use this form to compute maximum permissible lengths for duct runs to outdoors.

Note: Do not exceed maximum permissible equivalent lengths!

Flexible ducting: If flexible metal ducting is used, all the equivalent feet values in the table should be doubled. The flexible metal duct should be straight and smooth and extended as much as possible.

 

 

 

 

Total

 

 

Equivalent

Quantity

Equivalent

Duct Piece

Dimensions

Length*

Used

Length

 

 

1 ft.

 

 

 

6" round,

(per foot

 

 

 

straight

length)

 

 

 

 

1 ft.

 

 

 

3-1⁄4" x 10"

(per foot

 

 

 

straight

length)

 

 

 

6"

 

 

 

 

90° elbow

15 ft.

 

 

 

6"

 

 

 

 

45° elbow

9 ft.

 

 

 

3-1⁄4" x 10"

 

 

 

 

90° elbow

16 ft.

 

 

 

3-1⁄4" x 10"

 

 

 

 

45° elbow

5 ft.

 

 

Do NOT use flexible

 

 

plastic ducting.

3-1⁄4" x 10"

 

 

90° flat elbow

18 ft.

Gas Downdraft

Cooktop

Model ZGU365 150' maximum equivalent length

Note: Any home ventilation system, such as a cooktop with a downdraft exhaust mechanism, may interrupt the proper flow of combustion air and exhaust required by fireplaces, gas furnaces, gas water heaters and other naturally vented systems. To minimize the chance of inter- ruption of such naturally vented systems, follow the heating equipment manufacturer’s guidelines and safety standards such as those published by NFPA and ASHRAE.

6" round

 

to 3-1⁄4" x 10"

 

transition

7 ft.

3-1⁄4" x 10"

 

round to 6"

 

transition

5 ft.

6" round to

 

314" x 10"

 

transition

 

90° elbow

20 ft.

3-1⁄4" x 10" to 6"

 

round transition

 

90° elbow

12 ft.

6" round

 

wall cap

 

with damper

21 ft.

3-1⁄4" x 10"

 

wall cap

 

with damper

27 ft.

6" round

 

roof cap

20 ft.

 

 

6" round

 

roof vent

24 ft.

* Actual length of straight duct plus duct fitting

Total Duct Run

 

 

equivalent. Equivalent length of duct pieces are based

 

 

on actual tests conducted by GE Evaluation Engineer-

 

 

ing and reflect requirements for good venting

 

 

performance with any downdraft cooktop.

 

 

7

Page 7
Image 7
GE Monogram ZGU365 installation instructions Duct Fittings, Gas Downdraft Cooktop