JXBC57 Kit

For Outdoor Remote Blower Locations

The blower and motor assembly can be mounted on an outside wall. This kit provides a means to mount the blower outside with a protective cover.

Materials Required (not supplied)

Approved liquid tight service connections for use between the wire compartment on the base and inside the structure.

7 wire nuts or other approved connectors.

Six 5/16" dia. fasteners compatible with the type of material the base is being fastened to.

3-1/4" x 10" to 6" round transition.

3-1/4 x 10" duct, (or 6" round) sufficient length to reach the outdoor installation location.

Electrical cable and connectors, sufficient length to connect the downdraft vent to the remote blower location. 14-guage min. is recommended, must conform to local codes.

Tools required:

Pencil or chalk

Measuring tape

Drill with appropriate bits

Phillips head screwdriver

1/4" Nut driver

Wire nuts

Safely glasses

Step1

Check

Parts

Supplied

Separate the cover from the base assembly by removing 5 screws. Retain screws.

• Check to be sure all parts are present.

Package of screws

4 Hanger Brackets

Cover

Cover Plate

Outlet Plate

Base

Assembly

Junction Box

Outlet Pan

Damper

17

Page 17
Image 17
GE Monogram ZGU365 installation instructions JXBC57 Kit, Check Parts Supplied