RS-232 SERIAL CONTROL COMMANDS

#EDIDDETOLO Function

The #EDIDDETOLO function stores the Default EDID in any Local EDID.

Syntax:

#EDIDDETOLO param1 param2 param3...param9

Parameters:

 

 

param1

Input list

[0 - 16]

param2 - 9 (optional)

Input list

[1 - 16]

Notes:

By specifying 0 for param1, all inputs will receive the Default EDID or use param1 - param9 to specify individual local inputs which will receive the Default EDID.

#LOEDIDTOLO Function

The #LOEDIDTOLO function loads the specified EDID file to a specified local input via RS-232.

Syntax:

#LOEDIDTOLO param1 param2 param3

Parameters:

 

 

 

param1

Input

[1 - 16]

param2

EDID size

[1 - 2]

 

 

 

 

 

 

Value

Meaning

 

 

1

128 byte EDID

 

 

 

 

 

 

2

256 byte EDID

 

 

 

 

 

param3

eco

[0 - 1]

 

Notes:

Set param1 to a value of 0 in order to specify all inputs. When using HyperTermi- nal, param3 must be set to 1. Otherwise, set param3 to 0.