IP CONTROL - MAIN PAGE

The 16x16 DVI Matrix supports IP based control via an IP Control. To access this feature an IP address, subnet, gateway, and port need to be set on the

16x16 DVI Matrix (Default IP: 192.168.0.70 Subnet: 255.255.255.0 Gateway:

192.168.0.1 Port: 80). These settings must fall within your networks IP address range. Please consult your network administrator to obtain the proper IP address and settings for this product to properly communicate on your network.

The IP control setting can be configured via the RS-232 control interface. Once this has been accomplished, access using IP Control is possible.

Simply type the IP address that was assigned to the product in a web browser to access the Main Page. It should look like the image below.

MAIN PAGE

The Main Page will display the current status and can also be used to create routes.

To create a new route, follow the steps below:

1.Click on the check boxes of all of the outputs that you would like to route an input to.

2.Click on the input that will be routed to the selected outputs.

3.Click the “Switch” button to initiate the change(s).

This page will automatically refresh every minute, however, at anytime the “Refresh” button can be pressed to refresh the status of the matrix.

29

Page 32
Image 32
Gefen EXT-DVI-16416 manual IP Control Main