RS-232 SERIAL CONTROL COMMANDS

F Command

The F command returns the state of pin 14 of the DVI inputs.

Syntax:

f

Parameters:

None

Notes:

“High” is returned if +5V is enabled on the DVI input. “Low” is returned if +5V is disabled on the DVI input.

Using parameters with the F Command

Permits disabling / enabling of +5V for Fiber Optic Extenders.

Syntax:

f param1 param2

Parameters:

 

 

param1

DVI input

[1 - 16]

param2

State

[0 - 1]

 

 

 

 

Value

Meaning

 

0

Disable

 

1

Enable

 

 

 

Notes:

Setting param1 to a value of 0 will apply the value of param2 to all inputs.

17

Page 20
Image 20
Gefen EXT-DVI-16416 manual F command returns the state of pin 14 of the DVI inputs