RS-232 SERIAL CONTROL COMMANDS

#MASKOUT Function

The #MASKOUT function allows blanking of selected outputs.

Syntax:

#MASKOUT param1 param2

Parameters:

 

 

param1

Output

[1 - 16]

param2

Masking state

[0 - 1]

 

 

 

 

Value

Meaning

 

0

Unmask

 

1

Mask

Notes:

 

 

 

 

The current masking state will be lost if the unit is rebooted or power is lost.

#ACTIVEBOLO Function

The #ACTIVEBOLO function enables the boot loader.

Syntax:

#ACTIVEBOLO

Parameters:

None

Notes:

This command must be typed twice in order to activate the boot loader.