RS-232 SERIAL CONTROL COMMANDS

#PRDSEDID Function

The #PRDSEDID function reads the downstream EDID and sends it to the serial port.

Syntax:

#PRDSEDID param1

Parameters:

 

 

param1

A downstream display

[1 - 16]

#PRLOEDID Function

The #PRLOEDID function reads the local EDID of a specified input and spools it to the serial port.

Syntax:

#PRLOEDID param1

Parameters:

 

 

param1

Input

[1 - 16]

#PRBAEDID Function

The #PRBAEDID function reads the EDID file from the specified bank and sends it to the serial port.

Syntax:

#PRBAEDID param1

Parameters:

 

 

param1

Bank

[1 - 5]