Operator’s Manual | Third Edition • First Printing |
|
|
|
|
Maintenance
Observe and Obey:
Only routine maintenance items specified in this manual shall be performed by the operator.
Scheduled maintenance inspections shall be completed by qualified service technicians, according to the manufacturer's specifications and the requirements specified in the responsibilities manual.
Maintenance Symbols Legend
The following symbols have been used in this manual to help communicate the intent of the instructions. When one or more of the symbols appear at the beginning of a maintenance procedure, it conveys the meaning below.
Indicates that tools will be required to perform this procedure.
Indicates that new parts will be required to perform this procedure.
Check the Battery - DC Models
Proper battery condition is essential to good machine performance and safe operation. Improper fluid levels or damaged cables and connections can result in component damage and hazardous conditions.
Electrocution hazard. Contact with hot or live circuits could result in death or serious injury. Remove all rings, watches and other jewelry.
Bodily injury hazard. Batteries contain acid. Avoid spilling or contacting battery acid. Neutralize battery acid spills with baking soda and water.
Perform this test after fully charging the battery.
1Put on protective clothing and eye wear.
2Remove the battery vent caps.
3Check the battery acid level. If needed, replenish with distilled water to the bottom of the battery fill tube. Do not overfill.
4Install the vent caps.
12 | Genie AWP Super Series | Part No. 114002 |