Genie 114002 Electrocution Hazards, Tip-over Hazards, Minimum Safe, Voltage, Approach Distance

Models: 114002

1 36
Download 36 pages 44.42 Kb
Page 4
Image 4
Electrocution Hazards

Operator’s Manual

Third Edition • First Printing

 

 

 

 

SAFETY RULES

Electrocution Hazards

This machine, even with an optional fiberglass platform, is not electrically insulated and will not provide protection from contact with or proximity to electrical current.

Keep away from the machine if it contacts energized power lines or becomes electrically charged. Personnel on the ground or in the platform must not touch or operate the machine until energized power lines are shut off.

Maintain safe distances from electrical power lines and apparatus in accordance with applicable governmental regulations and the following chart.

 

Minimum Safe

Voltage

Approach Distance

Phase to Phase

Feet

Meters

0 to 300V

Avoid Contact

Allow for platform movement, electrical line sway or sag and movement due to strong or gusty winds.

Do not use the machine as a ground for welding.

Do not operate an AC powered machine or a DC battery charger unless using a 3-wire grounded extension cord connected to a grounded AC circuit. Do not alter or disable 3-wire grounded plugs.

Tip-over Hazards

Do not raise the platform unless the base is level, all four outriggers are properly installed and the leveling jacks firmly contact the floor.

Do not adjust or remove the outriggers while the platform is occupied or raised.

Do not move the machine while the platform is raised.

300V to 50KV

10

3.05

50KV to 200KV

15

4.60

200KV to 350KV

20

6.10

350KV to 500KV

25

7.62

 

 

 

500KV to 750KV

35

10.67

 

 

 

750KV to 1000KV

45

13.72

 

 

 

Do not place ladders or scaffolds in the platform or against any part of this machine.