Operator’s Manual

Third Edition • First Printing

 

 

 

 

MAINTENANCE

Check the Oil Lubricator Canister Drip Rate - Air Models

Maintaining the proper oil drip rate into the lubricator canister is essential to safe operation and good machine performance. Failure to maintain the proper drip rate could result in machine component damage.

1While raising the platform, visually inspect the oil lubricator sight gauge.

Result: There should be a maximum of 1 to 2 drops of oil visible in the sight gauge.

2To adjust the drip rate, turn the oil flow control valve clockwise to decrease the flow or counterclockwise to increase the flow.

3Repeat this procedure until the proper oil drip rate is achieved.

Scheduled Maintenance

Maintenance performed quarterly, annually and every two years must be completed by a person trained and qualified to perform maintenance on this machine according to the procedures found in the service manual for this machine.

Machines that have been out of service for more than three months must receive the quarterly inspection before they are put back into service.

Check the Air Filter/Regulator Canister - Air Models

It is essential to drain the air filter/regulator canister of water to ensure good air motor performance and service life. A water-filled canister could cause the air motor to perform poorly and continued use could cause component damage.

1Check the air filter/regulator canister for any water accumulation.

2If water is visible, loosen the drain plug at the bottom of the canister and allow the water to drain out.

3Tighten the drain plug.

14

Genie AWP Super Series

Part No. 114002

Page 16
Image 16
Genie 114002 manual Check the Oil Lubricator Canister Drip Rate Air Models, Scheduled Maintenance