Genie SILENTMAX 1000/1200 Travel Limits, Closing Garage Door Down Limits, Required Programming

Models: TRILOG 1200/1500 SC 1200/1500 SILENTMAX 1000/1200 1200/1500 GPOWER 900 POWERLIFT 900

1 24
Download 24 pages 32.79 Kb
Page 6
Image 6
TRAVEL LIMITS

3 Required Programming

TRAVEL LIMITS

Closing Garage Door (Down Limits) WARNING

Make sure doorway is in view and clear of obstacles and people to avoid injury or damage to property.

DO NOT operate this unit from wall console before LIMITS are set. Severe damage to the opener can occur.

The shuttle MUST be engaged to carriage BEFORE setting limits. See Installation Poster (if provided) or call Customer Service at 1-800-35GENIE or visit www.geniecompany.com

NOTE: If shuttle/bullet has NOT been engaged to carriage, do so now. See page 17.

NOTE: Before setting limits confirm wall console red indicator light (or backlight) is ON. If not illuminated, check for correct wiring or the Sure-Lock switch may be activated.

Closing Garage Door (Down Limits)

1

Lift the door open by hand until the shuttle/bullet

 

engages the carriage on the rail.

 

1

1

2

 

2

Press and hold the down arrow button (-) for

 

 

2 seconds until the long LED comes on blue

 

 

(round LED remains off).

 

 

 

PROGRAM

 

PROGRAM

 

SET

+

SET

 

HOLD

 

 

 

2 seconds

 

 

6

3

Release down arrow button (-)and the long LED

 

will begin flashing.

 

 

PROGRAM

 

 

SET

+

4 Press and hold the down arrow button (-)until garage door is fully closed on floor, then release.

PROGRAM

SET+

Press and hold the down arrow button (-) for HOLD

PROGRAM

SET+

NOTE: You have 30 seconds to execute each step. If you see two solid red or flashing LEDs on the Powerhead, you have run out of time and must go back to the beginning of the step and start over. You can restart as many times as necessary to complete each step.

(continued next page)