6 Maintenance and Adjustments

6 Maintenance and Adjustments

REGULAR MAINTENANCE (continued)

Screw drive models: Verify shuttle release lever is in ENGAGED

(UP) position (pull release handle toward opener and let go)

Chain/belt drive models: Verify bullet is engaged to carriage.

Pull/release cord down and back towards opener and let go.

Screw Drive

Belt/Chain Drive

Opener

Opener

Reset Open/Close Travel Limit

Performing all eleven (11) Limits/Force setting steps (see pages 6-8)erases previous Limits/Force settings.

NoTE: The opener will not close the door automatically unless the Safe-T-Beam®System is installed and Limits are programmed.

Disengaging and Engaging Carriage/Bullet

 

Engaged

 

Disengaged

Disengaged

Engaged

 

Operate door using a remote or wall console.

Door will re-attach itself to carriage assembly.

CORRECTIVE MAINTENANCE

Changing Light Bulbs

Screw Drive

Opener REGULAR MAINTENANCE (continued)

Screw DriveCORRECTIVE MAINTENANCEBelt/Chain DriveManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundEngaged

Disengaged

To engage shuttle to carriage, pull down and toward the opener.

To disengage shuttle from carriage, pull down on relaese hanfle.

Belt/Chain Drive

Opener Manual backgroundManual background

Disengaged

Engaged

To engage bullet to carriage, pull the release handle down and toward the opener.

To disengage bullet from carriage, pull relaese handle down and toward the door.

Manual background WARNING

Use extreme caution when working from a ladder or step stool.

When replacing light cover, make sure wires are not pinched or near moving parts.

1.Disconnect power to door opener.

Open powerhead light cover.

Remove light bulb(s).

Replace light bulb(s).

DO NOT use light bulbs with greater than 100 Watt rating, PowerLift® 900, GPower900 require light bulbs of no more than 60 watts. Compact CFL's may also be used.

Close powerhead light cover.

2.Reconnect power to door opener.

Test light operation.

Remote Battery Replacement

Replace remote battery with a CR 2032 coin cell battery.

1.Open remote case using a washer or coin that fits into the slot at top of remote.

2.Replace battery.

3. Align components and snap case closed.

(continued next page) 17