Technical Data This in formation i s for the following appliances:
Belling 60T side control & Be lling 60T/70T front control NG & LPG
Data badgeUnderside of the hob base
Electrical supply
Ignition
Mains repetitive ignition.
Gas connectionThe inlet connection is at the rear
ISO7 - Rp1/2” (1/2” BSP)
Appliance class
Class 3
Gas category
Natural Gas II2H3+
LPG only I3+
The a djustment conditions f or this appliance a re s tated on the d ata badge.
This appliance is factory set for either natural gas only or LPG only. If y ou wish to co nvert this h ob from natural gas to LP G, a conversion k it
Gas pressure settings
G20 Natural gas @ 20 mbar
G31 Propane gas @ 37 mbar
G30 Butane gas @ 28 - 30 mbar
Countries of destination (GB) Great Britain, (IE) Ireland
The Gas C onsumer Cou ncil (GCC) is an independent organisation which protects the interests of gas users. If you need advice, you will find the tele- phone number in your local telephone directory under gas.
Burner | Natural Gas |
| LP Gas |
|
|
|
| Bypass | |
| kW | Injector | kW | Injector |
| Grammes per hour | screw | ||
60T side control- |
|
| marking |
| marking |
| Butane | Propane | sizes |
|
|
|
| ||||||
Back LH | 2.0kW |
| 104 | 2.0kW | 70 | 1 | 45g/h | 143g/h | 32 |
Back RH | 2.0kW |
| 104 | 2.0kW | 70 | 145g/h | 143g/h | 32 | |
Front LH | 3.0kW |
| 129 | 3.0kW | 87 | 2 | 18g/h | 215g/h | 40 |
Front RH | 1.0kW |
| 77 | 1.0kW | 50 | 73g/h | 72g/h | 27 | |
|
|
|
|
|
|
|
|
|
|
60T/70T front control | - |
|
|
|
|
|
|
|
|
Back LH | 2.0kW |
| 104 | 2.0kW | 70 |
| 145g/h | 143g/h | 32 |
Back RH | 3.0kW |
| 129 | 3.0kW | 87 |
| 218g/h | 215g/h | 40 |
Wok | 3.5kW |
| 121 & 63 | 3.5kW | 87 & 35 |
| 254g/h | 250g/h | 68 |
Front RH | 2.0kW |
| 104 | 2.0kW | 70 |
| 145g/h | 143g/h | 32 |
Front LH | 1.0kW |
| 77 | 1.0kW | 50 |
| 73g/h | 72g/h | 27 |
|
|
|
|
|
|
|
|
|
|
Total Heat Input ∑Qn |
|
|
|
|
|
|
|
|
|
60T | 8.0kW |
|
| 8.0k W |
| 582g/h | 572g/h |
| |
70T | 11.5kW |
| - | 11.5kW | - |
| 836g/h | 822g/h | - |
|
|
|
|
|
|
|
|
|
|
20