Maintenance

Hose Electrical Resistance

Check electrical resistance of hoses regularly. If total resistance to ground exceeds 29 megohms, replace hose immediately.

Filters

Once a week check, clean, and replace (if needed) the following filters.

Both pump filters; see lower manual for instructions.

Main air inlet manifold filter; see Replace Air Filter Element, page 36.

Spray gun handle filter; see spray gun manual.

Seals

Once a week, check and tighten throat seals on both

pumps. See table for torque specifications. Be sure to follow the Pressure Relief Procedure, page 22, prior to

tightening seals. There must be zero pressure on the pumps when adjusting.

Pump Size

Torque Specification

 

 

All

25-30 ft-lb (34-41 N•m)

 

 

Cleaning Procedure

1.Ensure all equipment is grounded. See Grounding, page 18.

2.Ensure the area where the system will be cleaned is well ventilated and remove all ignition sources.

3.Turn off all heaters and allow equipment to cool.

4.Flush mixed material. See Flush Mixed Material, page 28.

5.Relieve pressure. See Pressure Relief Procedure, page 22.

6.Shutdown the sprayer and turn off all power. See

Shutdown, page 30.

7.Clean the external surfaces only using a rag soaked in solvent that is compatible with the spray material and surfaces being cleaned.

8.Allow enough time for the solvent to dry before using the system.

Recommended Spare Parts

Keep these spare parts on hand to reduce downtime. See Recommended Spare Parts, page 54.

Change the Mix Ratio

In order to change the mix ratio, one or both pumps need to be replaced, the air motor needs to be re-posi- tioned, and the over pressure relief valves may need to be installed.

NOTE: Only Xtreme XP lower pumps come with a rod coupling.

1.Check the Varying Parts table on page 51 for the correct pump sizes.

2.Remove and replace pump. See page 35.

3.Adjust the position of the air motor. See page 20.

4.If changing from one type of XP system to another (for example - changing from XP35 to XP70 or from XP70 to XP35): remove the existing

over pressure relief valves (302) and install the cor- rect valves for the new system type. See Replace Over Pressure Relief Valves on page 38.

5.Change air pressure relief valve as required, depending on ratio. See air relief valve (64) in tables starting on page 46.