Repair

7.Slide handle (311) onto valve stem and rotate approximately 90° until you feel it fully lock against the valve seat. Repeat for opposite side.

8.Remove handle then place handle (311) on valve stem (302) at the vertical, or near vertical, position.

9.Apply blue threadlock on the nut (304) threads and tighten the handle against the spring (320) and clip (318). Torque to 70-80 in-lb (7.9-9 N•m).

10.Place the rod (312) and the second handle (311) on second valve stem aligned with the opposite handle.

11.Repeat step 9.

12.Install two screws (313) in handles (311).

13.Check operation of the handle and valves.

14.Operate the handle in and out of the spray and cir- culate positions.

15.Check for clearance with fittings.

NOTE:

Both valves should settle firmly into the spray position inward against the seats in the valve.

Both valve stems should rotate out to their most extended positions when the handle is pulled down to the circulate position.

Fluid Circulation Manifold Replacement Guide

Colored Valve Sleeve

 

 

 

 

ti19169a

 

 

ti19168a

 

 

Circulation

Relief

 

Target Opening

 

Manifold (35)

Valve (302)

Valve Sleeve

Pressure

 

Part No.

Part No.

Color

psi (MPa, bar)

Use with:

 

 

 

 

All XP35 models,

262784

262808

Purple

5300 (37, 365)

XP-h models 284101,

 

 

 

 

284201, 284301, 284401

 

 

 

 

All XP50 models,

262783

262809

Gold

7100 (49, 490)

XP-h models 284102,

 

 

 

 

284202, 284302, 284402

 

 

 

 

All XP70 models,

262806

262520

Silver

9250 (64, 638)

XP-h models 284103,

 

 

 

 

284203, 284303, 284403

NOTE: Original XP70 valves did not include a silver valve sleeve. When replacing these original valves, replace with the current valves that have the silver valve sleeve.